The field proven Military Power® UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1488 was specifically designed for systems requiring high density power with 3-phase input. The ETI0001-1488 does not require a separate PDU since the PDU functions are already integrated into the UPS module. This saves rack space, cabling and expense while improving overall reliability.

The heavy-duty chassis occupies only 6U (10.5”) of rack space. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis. These units can be mounted horizontally or vertically. Optional heavy-duty rack slides provide easy installation and removal of the unit with full extension.

The internal shielded input transformer provides galvanic isolation with provisions for nominal 208 VAC, 3-phase input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the isolation transformer provide an isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent. 50or 400 hertz outputs are available as an option.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The high intensity audible alarm can be heard in high noise environments and includes an audible disable switch. All controls and protective devices are brought to the front and rear panels with critical switches or circuit breakers having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battle-short override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console with only a logic level cable connection.

The rear panel provides locking MS threaded metal shell connectors for the input and output power with various optional configurations available. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The UPS Remote Control and the PDU Remote Control connectors provide an interface to optional remote display/control panels.

This unit draws air through the front air filter and exhausts out the rear vent into the rack. This allows the unit to be used in negative or neutral pressure racks. For positive pressure racks, rear to front or rear to side versions are available. The removable and washable metal screen air filters and high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments.

The ETI0001-1488 has the added benefit of having afield replaceable battery via a rear draw-out battery module. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials.

For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

For more information see the Power Distribution Units section for a listing of stand alone PDUs

Also available in this series is the ETI0001-1488A1.  Inquire for more in this product variant.

Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

ETI0001-1488, 5000 VA UPS, with 3-Phase Intelligent PDU

Rugged Mil Spec® 5000 VA Integrated
120 VAC Power Source with
3-Phase Input and 1-Phase Output
Rackmount UPS and Intelligent
Power Distribution Unit Combination

Military Power® Mil Spec N5Configuration
5000 VA Rugged Rack MountIsolated AC and DC UPS w/ Integrated
8 Circuit, 2 Pole, Intelligent, Solidstate Power Distribution Unit
Intelligent SNMP/HTTP Interface

The field proven Military Power® UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1488 was specifically designed for systems requiring high density power with 3-phase input. The ETI0001-1488 does not require a separate PDU since the PDU functions are already integrated into the UPS module. This saves rack space, cabling and expense while improving overall reliability.

The heavy-duty chassis occupies only 6U (10.5”) of rack space. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis. These units can be mounted horizontally or vertically. Optional heavy-duty rack slides provide easy installation and removal of the unit with full extension.

The internal shielded input transformer provides galvanic isolation with provisions for nominal 208 VAC, 3-phase input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the isolation transformer provide an isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent. 50or 400 hertz outputs are available as an option.

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The high intensity audible alarm can be heard in high noise environments and includes an audible disable switch. All controls and protective devices are brought to the front and rear panels with critical switches or circuit breakers having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battle-short override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console with only a logic level cable connection.

The rear panel provides locking MS threaded metal shell connectors for the input and output power with various optional configurations available. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The UPS Remote Control and the PDU Remote Control connectors provide an interface to optional remote display/control panels.

This unit draws air through the front air filter and exhausts out the rear vent into the rack. This allows the unit to be used in negative or neutral pressure racks. For positive pressure racks, rear to front or rear to side versions are available. The removable and washable metal screen air filters and high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments.

The ETI0001-1488 has the added benefit of having afield replaceable battery via a rear draw-out battery module. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials.

For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

For more information see the Power Distribution Units section for a listing of stand alone PDUs

Also available in this series is the ETI0001-1488A1.  Inquire for more in this product variant.

Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications

ETI0001-1488

AC OUTPUT
Output voltage: 120 VAC true sinewave standard
Output rating: UPS 5000 VA standard in 6U chassis x 23.5″ deep
0.65-0.75 pf standard
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz ± 2.5% synchronized to utility
60 Hz ± 1.0% w/ utility not available
50, 400 or 1000 Hz output available as an option
Operational status AC Input status, UPS operational, UPS alarm, Battery level, Low battery, Load level, Overload LEDs, Elapsed time hour meter
Alarm contacts for Loss of AC and Low Battery
+90 dB audible alarm with audible on/off switch
AC INPUT
Input voltage: Nominal 208 VAC L-L, 3-phase
Input voltage tolerance: UPS 148-234 VAC @ full load without using battery
Input frequency: From 46 Hz to 70 Hz standard, optional to 440 Hz
Input power factor: Better than 99% typically
Input/output isolation: 6000 VA, up to 120 dB common mode, <1.0 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 3 pole 100 G shock rated circuit breaker (CB1)
plus UPS input fuses (F2A, F2B and F2C)
Input power connections: MS 3102R-24-22P, 4 pin, locking
INTERNAL BATTERY
Internal battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal battery life: Rated for continuous service life of 5 years
Internal DC protection: Panel mounted fuse standard, breaker optional
Internal battery time: 5 minutes typical
Internal battery recharge: Recharged to nominal in 8 hours
DISTRIBUTION PANEL
Output circuits: Eight controlled outputs via solidstate relays
Output control: Local/remote control panel w/individual load switches
Thermal and remote interlock ON/OFF control
Output receptacles: NEMA 5-15R threaded locking, various options
MECHANICAL
Dimensions ( H x D x W ): 10.5 (6U) x 23.5 x 19.0 in (267 x 597 x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns standard, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight: Total
UPS w/o Battery Module
169 lb. ( 77 kg) with lift handles front and rear
105 lb. ( 48 kg) with lift handles front and rear
Audible noise: Less than 47 dB @ 5.0 ft., ANSI “A” scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Front intake, exhaust to rear
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C) with fully charged batteries
Operating temperature: 32° to 122° F ambient ( 0° to 50° C), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461

Additional information

Weight 105 lbs
Dimensions 18.5 × 19 × 7 in