The field-proven PowerStation™ UPS line is ideally suited for military, industrial, medical and telecommunications applications requiring high reliability, rugged construction, compact size and lightweight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1260A5” is being used by the US military because of its stringent performance and reliability requirements.

The heavy-duty chassis, occupying only  3U (5.25″) of rack space and 23.5″ depth, has rounded metal corners and rugged front-mounted handles, aiding in safe handling. Companion 2U (3.5″ high) Battery Expansion Modules are designed to be daisy-chained to bring up the backup time in the typical configuration.  In the typical application, the base UPS unit and up to four Battery Modules are mounted in the lower underside of a rack or cart. Both module chassis is constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra-low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60-hertz power. The input switch and the galvanic isolation transformer all provide a  double pole isolated source for systems or locations where phase references and grounding are not consistent.  For scenarios that need hospital-grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides a locking connector for the input power and NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high-capacity stainless steel ball-bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The “ETI0001-1260A5” has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further.

This series of products includes:

  • ETI0001-1260: Listed on NSN 6130-01-498-9063
  • ETI0001-1260AA: 4000 VA UPS, Internal Isolation,  Operational to 55º C,  Reverse Airflow (Front to Rear), Frequency Converter
  • ETI0001-1260AD:  Inquire for details on that variation.
  • ETI0001-1260AJ: listed on NSN: 6130-01-604-0946  Inquire for details on that variation.
  • ETI0001-1260A5: This is the ETI0001-1260AJ UPS & ETI0002-0651 BATT MODULE.  NSN # 6130-01-604-9747
  • See the Power Distribution Units section for a listing of stand alone PDUs
  • See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

ETI0001-1260A5 4.0 kVA UPS & Frequency Converter

UPS

  • Mil Spec UPS Rugged Rackmount
  • NSN: 6130-01-604-9747
  • 4.0 kVA UPS and Frequency Converter
  • Rugged Rack or Fixed Mount Unit
  • Reduced Depth
  • ETI0002-0651 Battery Module for Hours of Battery Backup between Locations
  • Accepts both Aircraft Power and Commercial Power
  • Includes ETI0002-0582 battery module

The field-proven PowerStation™ UPS line is ideally suited for military, industrial, medical and telecommunications applications requiring high reliability, rugged construction, compact size and lightweight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The "ETI0001-1260A5" is being used by the US military because of its stringent performance and reliability requirements.

The heavy-duty chassis, occupying only  3U (5.25") of rack space and 23.5" depth, has rounded metal corners and rugged front-mounted handles, aiding in safe handling. Companion 2U (3.5" high) Battery Expansion Modules are designed to be daisy-chained to bring up the backup time in the typical configuration.  In the typical application, the base UPS unit and up to four Battery Modules are mounted in the lower underside of a rack or cart. Both module chassis is constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra-low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60-hertz power. The input switch and the galvanic isolation transformer all provide a  double pole isolated source for systems or locations where phase references and grounding are not consistent.  For scenarios that need hospital-grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides a locking connector for the input power and NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high-capacity stainless steel ball-bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The "ETI0001-1260A5" has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further.

This series of products includes:

  • ETI0001-1260: Listed on NSN 6130-01-498-9063
  • ETI0001-1260AA: 4000 VA UPS, Internal Isolation,  Operational to 55º C,  Reverse Airflow (Front to Rear), Frequency Converter
  • ETI0001-1260AD:  Inquire for details on that variation.
  • ETI0001-1260AJ: listed on NSN: 6130-01-604-0946  Inquire for details on that variation.
  • ETI0001-1260A5: This is the ETI0001-1260AJ UPS & ETI0002-0651 BATT MODULE.  NSN # 6130-01-604-9747
  • See the Power Distribution Units section for a listing of stand alone PDUs
  • See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Additional information

Dimensions 18.5 × 19 in

Technical Specifications

Tell Us About Your Needs

*(denotes required field)
prime contractors

Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466

// code for product search below