The field proven PowerStation™ UPS line is ideally suited for military, industrial, medical and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1260AA” is being used by the US military because of their stringent performance and reliability requirements.

The heavy-duty chassis, occupying only  3U (5.25″) of rack space and 23.5″ depth, has rounded metal corners and rugged front mounted handles, aiding in safe handling. Companion 2U (3.5″ high) Battery Expansion Modules are designed to be daisy chained to bring up the backup time in the typical configuration.  In the typical application, the base UPS unit and up to four Battery Modules are mounted in the lower underside of a rack or cart. Both module chassis are constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a  double pole isolated source for systems or locations where phase references and grounding are not consistent.  For scenarios that need hospital grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides a locking connector for the input power and NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The “ETI0001-1260AA” has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further.

This series of products includes:

  • ETI0001-1260: Listed on NSN 6130-01-498-9063
  • ETI0001-1260AA: 4000 VA UPS, Internal Isolation,  Operational to 55º C,  Reverse Airflow (Front to Rear), Frequency Converter
  • ETI0001-1260AD  Inquire for details on that variation.
  • ETI0001-1260AJ listed on NSN: 6130-01-604-0946  Inquire for details on that variation.
  • ETI0001-1260A5: This is the ETI0001-1260AJ UPS & ETI0002-0651 BATT MODULE.  NSN # 6130-01-604-9747
  • See the Power Distribution Units section for a listing of stand alone PDUs
  • See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

ETI0001-1260 Series 4.0 kVA UPS & Frequency Converter

UPS

  • Mil Spec UPS Rugged Rackmount
  • NSN: 6130-01-498-9063
  • 4.0 kVA UPS and Frequency Converter
  • Rugged Rack or Fixed Mount Unit
  • Reduced Depth
  • Multiple Battery Modules for Hours of Battery Backup between Locations
  • Accepts both Aircraft Power and Commercial Power
  • Includes ETI0002-0582 battery module

The field proven PowerStation™ UPS line is ideally suited for military, industrial, medical and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The "ETI0001-1260AA" is being used by the US military because of their stringent performance and reliability requirements.

The heavy-duty chassis, occupying only  3U (5.25") of rack space and 23.5" depth, has rounded metal corners and rugged front mounted handles, aiding in safe handling. Companion 2U (3.5" high) Battery Expansion Modules are designed to be daisy chained to bring up the backup time in the typical configuration.  In the typical application, the base UPS unit and up to four Battery Modules are mounted in the lower underside of a rack or cart. Both module chassis are constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a  double pole isolated source for systems or locations where phase references and grounding are not consistent.  For scenarios that need hospital grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides a locking connector for the input power and NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The "ETI0001-1260AA" has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further.

This series of products includes:

  • ETI0001-1260: Listed on NSN 6130-01-498-9063
  • ETI0001-1260AA: 4000 VA UPS, Internal Isolation,  Operational to 55º C,  Reverse Airflow (Front to Rear), Frequency Converter
  • ETI0001-1260AD  Inquire for details on that variation.
  • ETI0001-1260AJ listed on NSN: 6130-01-604-0946  Inquire for details on that variation.
  • ETI0001-1260A5: This is the ETI0001-1260AJ UPS & ETI0002-0651 BATT MODULE.  NSN # 6130-01-604-9747
  • See the Power Distribution Units section for a listing of stand alone PDUs
  • See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications

Product Support Services

Warranty Coverage

  1. First Year Standard Warranty- The Energy Technologies’ Standard Warranty covers labor and material (excluding batteries) for the first year after shipment; however, this warranty excludes travel and living expenses. Refer to the Warranty section of this manual.
  2. Extended Warranty (Optional)- For those customers who desire to purchase service over and above the Standard Warranty, ETI will provide a quote for a service plan to meet your requirements. Typical plans include the following:
  3. Extended Warranty OptionThis plan provides for replacement parts as an extension to the Standard Warranty one-year period.
  4. Limited Full Service Plan OptionThe Limited Full Service Plan extends the Standard Warranty beyond the initial one-year period, and includes travel and living expenses for the warranty period. This plan can be offered with or without preventive maintenance.

 

Return Material Authorization

If the product requires service for any reason, the customer should contact the Customer Service Department. If the product must be returned to ETI for repair or replacement, the customer must obtain a Return Materials Authorization (RMA) number. The product must be packed in the original shipping container or other equally suitable container. The product must be shipped prepaid with the RMA number on the packing slip. Unauthorized returns of units will be subject to an inspection and handling charge plus any repair and all transportation charges.

Note

If you have to return the unit for repair, it is imperative that it be packaged properly! Due to the weight of the unit and the potential for mishandling, the unit carton must be strapped to a skid before shipping. This forces the freight company to use a tow motor to move the unit. When a skid is not used, there are stages in handling where the carton will be manhandled and inevitably gets dropped on its ends. Foam packs and other packing fillers alone are not adequate to avoid mechanical damage. Energy Technologies, Inc. will not be liable and a breach of warranty will occur if:
1) a skid is not used
2) proper handling is not maintained.

 

Standard Warranty Policy

Energy Technologies, Incorporated (ETI) warrants against faulty materials or workmanship for equipment sold new and delivered pursuant to the terms of any agreement between ETI and customer for one (1) year from the original date of shipment of the equipment. The warranty is limited to repair or replacement during the warranty period at the sole discretion of ETI. It is the responsibility of the customer to notify and return the defective product to ETI, with all costs for shipment of the product to and from ETI paid by the customer. The defective product must be returned intact and shall appear to ETI upon inspection that the failure of the product was caused by defective material or workmanship. Such repair or replacement shall be made free of charge if the defect is determined to be caused from faulty material and/or workmanship, the unit is within the warranty period, and ETI was notified within the warranty period.

This warranty, however,
(a) extends only to, and is intended for the benefit only of, customer (original purchaser), and does not obligate, and shall not be construed to obligate, ETI to any person or organization other than customer.
(b) is effective only when customer returns such defective part or parts to ETI’s factory, transportation prepaid, immediately upon customer’s discovery of the defect in question.
(c) is not effective when the part or product in question is, or has been, operated beyond rated capacity, used or applied improperly, or used with parts which are not made or recommended by ETI.
(d) does not render ETI liable for any claims or claims for damages which may result, directly or indirectly, from any defect in any part or parts manufactured by ETI; except to replace the part or parts in question.

In lieu of returning defective part or parts to ETI’s factory as specified in subparagraph (b) of the foregoing standard warranty, the customer may request ETI to make necessary repairs on site. If ETI agrees that such on-site repairs are practical, ETI shall supply parts and labor for this purpose free of charge; however, the customer shall pay ETI’s traveling expenses to and from said site and living expenses of such personnel while traveling and while on site. If the required repairs are found to be caused by the mishandling, misuse or misapplication of equipment furnished by ETI and/or the required repairs are covered by the ETI Operations and Maintenance Manual, then ETI shall supply labor at the per diem rate normally charged for field service. Parts to be in accordance with ETI’s spare parts prices.

The warranty shall be void if:
(a) the equipment is damaged by the customer, is improperly used, is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifications.
(b) the equipment is repaired or modified by anyone other than ETI or ETI approved personnel.
(c) has been used in a manner contrary to the products operating manual or other written instructions.

ETI reserves the right to make changes, additions, and/or improvements in its products without incurring any obligation to install them on its products previously manufactured and/or sold. No provision of this warranty shall cover the installed batteries. However, the battery manufacturer’s warranties shall be passed through to the customer whenever applicable. ETI will not be liable for any associated costs incurred by the user or installing contractor as a direct or indirect result of failure or in the replacement of defective in-warranty material. The customer MUST obtain a Return Material Authorization from ETI’s Customer Service Department before returning a product for warranty service. The return authorization number MUST be placed on the outside of the shipping box and the equipment must be packaged securely to avoid damage during shipping. Unauthorized returns for in-warranty repairs may be rejected or subject to an inspection and handling charge of $75 plus any repair and all transportation charges.

The warranty is expressly in lieu of all other warranties, expressed or implied, including, and without limitation, any implied warranty or merchantability or fitness for a particular purpose, and/or any other obligation or liability on the part of Energy Technologies Inc. The sole exclusive remedy for breach of any warranty, expressed or implied, concerning ETI’s products and the only obligation of ETI hereunder, shall be the repair or replacement of defective equipment, components, or parts, or, at ETI’s option, the refund of the purchase price or substitution with a new replacement product. ETI shall in no way be responsible for any consequential damages, of any kind, or nature whatsoever, resulting from the breach of any warranty.

Tell Us About Your Needs

*(denotes required field)
prime contractors

Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466

// code for product search below