The field-proven Tactical Power® UPS line is ideally suited for military, industrial, commercial, and telecommunications applications that require a high-quality, high-reliability power source that is rugged in construction yet lightweight, compact, and mobile. These units are equally suited for use in the field or aboard vehicles, marine vessels, or aircraft in both controlled or hostile environments. The ETI0019-2120EC is specifically designed for global deployment while delivering up to 2000 VA / 1500 Watts of uninterruptible computer-grade power to critical loads such as computers.

This UPS is built into a heavy-duty case the size of airline carry-on luggage and includes a popup handle and wheels. When the case cover is closed, the unit becomes watertight. The rounded corners and rugged handles aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to mechanical shock and vibration. As a portable UPS, the unit can be used in either a horizontal or vertical position.

Designed for both domestic (CONUS) and international (OCONUS) input voltages, this unit’s auto-ranging input voltage selection accepts any AC voltage from 90 to 264 VAC (i.e. nominal 100, 115, 120, 200, 220, 230 or 240 VAC sources) and any frequency from 47 to 63 (i.e. nominal 50 or 60 Hz sources) without special cables or having to open the UPS enclosure. Alternately, the unit also accepts vehicular or aircraft power from nominal 24 VDC systems. This allows the unit to be operated when no AC source is available. Optional 12 VDC and 48 VDC versions are also available.

The high-reliability LED arrays to keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments. For situations requiring more stealth, the LEDs can be dimmed or extinguished and the audible feature disabled. All controls and protective devices are brought to the front panel with critical controls having finger guards to prevent damage or accidental operation.

The ETI0019-2120EC has the added benefit of having a field-replaceable battery via the front drawout battery module. Even if this battery module is removed or depleted, this UPS can continue to operate as an electronic power conditioner and frequency converter, providing clean, well-regulated, sinusoidal power to the load. The VRLA AGM batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials for added safety. For more information, see the Battery Technology section.Tactical UPS Front Panel Layout

A removable and washable intake air filter and high capacity stainless steel ball-bearing fans provide added protection in both controlled and hostile environments.

Maintaining documentation for equipment in the field has always been an issue. Instead of having to carry bulky paper documentation, the ETI0019-2120EC incorporates the eDocs Port™, a patented feature unique to Energy Technologies, Inc. This flash drive contains all the relevant documentation for the unit at hand. This includes Operation and Maintenance manuals as well as training and troubleshooting guides. Utilizing a standard USB interface, these standardized electronic documents are readily available to the user.

Overall, the Tactical Power line is uniquely qualified for the critical vehicle, airborne, shipboard, or land based systems combining advanced modular design features with highly reliable construction.

ETI0019-2120EC, 1500 Watt Tactical Wheeled Carry-On UPS

Rating: 2000 VA, 1500 Watts
Input: 90-264 VAC, 47-63 Hz or
Input: 21-30 VDC
Output: 220 VAC, 50 or 60 Hz

The field-proven Tactical Power® UPS line is ideally suited for military, industrial, commercial, and telecommunications applications that require a high-quality, high-reliability power source that is rugged in construction yet lightweight, compact, and mobile. These units are equally suited for use in the field or aboard vehicles, marine vessels, or aircraft in both controlled or hostile environments. The ETI0019-2120EC is specifically designed for global deployment while delivering up to 2000 VA / 1500 Watts of uninterruptible computer-grade power to critical loads such as computers.

This UPS is built into a heavy-duty case the size of airline carry-on luggage and includes a popup handle and wheels. When the case cover is closed, the unit becomes watertight. The rounded corners and rugged handles aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to mechanical shock and vibration. As a portable UPS, the unit can be used in either a horizontal or vertical position.

Designed for both domestic (CONUS) and international (OCONUS) input voltages, this unit's auto-ranging input voltage selection accepts any AC voltage from 90 to 264 VAC (i.e. nominal 100, 115, 120, 200, 220, 230 or 240 VAC sources) and any frequency from 47 to 63 (i.e. nominal 50 or 60 Hz sources) without special cables or having to open the UPS enclosure. Alternately, the unit also accepts vehicular or aircraft power from nominal 24 VDC systems. This allows the unit to be operated when no AC source is available. Optional 12 VDC and 48 VDC versions are also available.

The high-reliability LED arrays to keep the operator informed as to the unit's status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments. For situations requiring more stealth, the LEDs can be dimmed or extinguished and the audible feature disabled. All controls and protective devices are brought to the front panel with critical controls having finger guards to prevent damage or accidental operation.

The ETI0019-2120EC has the added benefit of having a field-replaceable battery via the front drawout battery module. Even if this battery module is removed or depleted, this UPS can continue to operate as an electronic power conditioner and frequency converter, providing clean, well-regulated, sinusoidal power to the load. The VRLA AGM batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials for added safety. For more information, see the Battery Technology section.Tactical UPS Front Panel Layout

A removable and washable intake air filter and high capacity stainless steel ball-bearing fans provide added protection in both controlled and hostile environments.

Maintaining documentation for equipment in the field has always been an issue. Instead of having to carry bulky paper documentation, the ETI0019-2120EC incorporates the eDocs Port™, a patented feature unique to Energy Technologies, Inc. This flash drive contains all the relevant documentation for the unit at hand. This includes Operation and Maintenance manuals as well as training and troubleshooting guides. Utilizing a standard USB interface, these standardized electronic documents are readily available to the user.

Overall, the Tactical Power line is uniquely qualified for the critical vehicle, airborne, shipboard, or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications

Portable Global Input 2000 VA UPS
P/N: ETI0019-2120EC
AC OUTPUT
Output voltage (standard): 220 VAC true sinewave output standard setting
230 or 240 VAC optional settings available
Output voltage (optional): 100, 110 or 120 VAC version available, see ETI0019-2120EA
Output rating (standard): 2000 VA, 1500 watts standard
Output rating (optional): 1000 VA, 700 watts version available, see ETI0019-2110EC
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: ± 3.0% static regulation of nominal
± 5.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: 60 Hz or 50 Hz switch selectable
Operational status: AC Input status, UPS operational, Battery level, Low battery,
Load level, Overload LEDs, audible alarm w/audible on/off switch
AC INPUT
Input voltage (AC Input): Autoranging from nominal 90 VAC to 264 VAC
Input frequency: From 47 Hz to 63 Hz standard, optional up to 440 Hz
Input power factor: Better than 95% typically
Input/output isolation: up to 120 dB common mode, <2.0 ma leakage
Input transient suppression: Complies with IEEE 587, UL 1449 and Mil Std 1399
Input control/protection: Guarded circuit breaker
Input power connections: One IEC 60320-C20 male, 3 pin with cable restraint
Input power cable: One 6′ cord w/IEC 60320-C19 female and NEMA 5-15P
Input power cable adapters: One kit of universal plug adapters for most global outlets
DC INPUT / INTERNAL BATTERY
External DC input (standard): 24 VDC Nominal 21 to 30 VDC
External DC input (optional): 12 VDC Nominal 10.5 to 15 VDC version available, see ETI0019-2120ED
External DC input (optional): 48 VDC Nominal 42 to 60 VDC version available, see ETI0019-2120EF
External DC control/protection: Thermal circuit breaker
External DC connector: CPC, 7 pin, locking
Internal battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal battery life: Rated for continuous service life of 5 years
Internal battery time: 5+ minutes @ 750 watt load, 15+ minutes @ 375 watt load
Internal battery recharge: Recharged to nominal in <8 hours
Internal battery replacement: Drawout/plug-in module from front of unit
<5 minutes to change battery modules
Battery expansion: Up to 24 hours w/ optional Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Four AC outputs standard, several optional configurations
Output protection (standard): One GFCI (Ground Fault Circuit Interrupter) duplex, one standard duplex
Output protection (optional): Individual push/pull circuit breakers available for each outlet
Output receptacles: AC output NEMA 5-15R with dust covers, others optional
MECHANICAL
Dimensions (H x D x W): 21.75 x 8.99 x 13.75 in (552 x 228 x 349 mm)
Unit weight:
UPS and Battery
UPS only
Battery Module only
50 lb. (23 kg) with lift handles front and rear
24 lb. (11 kg) with lift handles front and rear
26 lb. (12 kg) with lift handle in front
Audible noise: Less than 47 dB @ 5.0 ft., ANSI “A” scale
Cooling type: High capacity, positive pressure, forced air
Air intake filter: Washable filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C)
Operating temperature: 32° to 126° F ambient ( 0° to 52° C), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 50,000 ft (15,240 m), higher optional
Operating elevation: Up to 10,000 ft (3,048 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
Meets MIL-STDs 1275, 167-1, 454, 810, 1399-300A & MIL-S-901
Canada: Meets CSA C22.2 No. 107 UPS safety requirements
EMI Protection: Meets EMI/RFI FCC Part 15, Class A; EN55022

Product Support Services

Warranty Coverage

  1. First Year Standard Warranty- The Energy Technologies’ Standard Warranty covers labor and material (excluding batteries) for the first year after shipment; however, this warranty excludes travel and living expenses. Refer to the Warranty section of this manual.
  2. Extended Warranty (Optional)- For those customers who desire to purchase service over and above the Standard Warranty, ETI will provide a quote for a service plan to meet your requirements. Typical plans include the following:
  3. Extended Warranty OptionThis plan provides for replacement parts as an extension to the Standard Warranty one-year period.
  4. Limited Full Service Plan OptionThe Limited Full Service Plan extends the Standard Warranty beyond the initial one-year period, and includes travel and living expenses for the warranty period. This plan can be offered with or without preventive maintenance.

 

Return Material Authorization

If the product requires service for any reason, the customer should contact the Customer Service Department. If the product must be returned to ETI for repair or replacement, the customer must obtain a Return Materials Authorization (RMA) number. The product must be packed in the original shipping container or other equally suitable container. The product must be shipped prepaid with the RMA number on the packing slip. Unauthorized returns of units will be subject to an inspection and handling charge plus any repair and all transportation charges.

Note

If you have to return the unit for repair, it is imperative that it be packaged properly! Due to the weight of the unit and the potential for mishandling, the unit carton must be strapped to a skid before shipping. This forces the freight company to use a tow motor to move the unit. When a skid is not used, there are stages in handling where the carton will be manhandled and inevitably gets dropped on its ends. Foam packs and other packing fillers alone are not adequate to avoid mechanical damage. Energy Technologies, Inc. will not be liable and a breach of warranty will occur if:
1) a skid is not used
2) proper handling is not maintained.

 

Standard Warranty Policy

Energy Technologies, Incorporated (ETI) warrants against faulty materials or workmanship for equipment sold new and delivered pursuant to the terms of any agreement between ETI and customer for one (1) year from the original date of shipment of the equipment. The warranty is limited to repair or replacement during the warranty period at the sole discretion of ETI. It is the responsibility of the customer to notify and return the defective product to ETI, with all costs for shipment of the product to and from ETI paid by the customer. The defective product must be returned intact and shall appear to ETI upon inspection that the failure of the product was caused by defective material or workmanship. Such repair or replacement shall be made free of charge if the defect is determined to be caused from faulty material and/or workmanship, the unit is within the warranty period, and ETI was notified within the warranty period.

This warranty, however,
(a) extends only to, and is intended for the benefit only of, customer (original purchaser), and does not obligate, and shall not be construed to obligate, ETI to any person or organization other than customer.
(b) is effective only when customer returns such defective part or parts to ETI’s factory, transportation prepaid, immediately upon customer’s discovery of the defect in question.
(c) is not effective when the part or product in question is, or has been, operated beyond rated capacity, used or applied improperly, or used with parts which are not made or recommended by ETI.
(d) does not render ETI liable for any claims or claims for damages which may result, directly or indirectly, from any defect in any part or parts manufactured by ETI; except to replace the part or parts in question.

In lieu of returning defective part or parts to ETI’s factory as specified in subparagraph (b) of the foregoing standard warranty, the customer may request ETI to make necessary repairs on site. If ETI agrees that such on-site repairs are practical, ETI shall supply parts and labor for this purpose free of charge; however, the customer shall pay ETI’s traveling expenses to and from said site and living expenses of such personnel while traveling and while on site. If the required repairs are found to be caused by the mishandling, misuse or misapplication of equipment furnished by ETI and/or the required repairs are covered by the ETI Operations and Maintenance Manual, then ETI shall supply labor at the per diem rate normally charged for field service. Parts to be in accordance with ETI’s spare parts prices.

The warranty shall be void if:
(a) the equipment is damaged by the customer, is improperly used, is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifications.
(b) the equipment is repaired or modified by anyone other than ETI or ETI approved personnel.
(c) has been used in a manner contrary to the products operating manual or other written instructions.

ETI reserves the right to make changes, additions, and/or improvements in its products without incurring any obligation to install them on its products previously manufactured and/or sold. No provision of this warranty shall cover the installed batteries. However, the battery manufacturer’s warranties shall be passed through to the customer whenever applicable. ETI will not be liable for any associated costs incurred by the user or installing contractor as a direct or indirect result of failure or in the replacement of defective in-warranty material. The customer MUST obtain a Return Material Authorization from ETI’s Customer Service Department before returning a product for warranty service. The return authorization number MUST be placed on the outside of the shipping box and the equipment must be packaged securely to avoid damage during shipping. Unauthorized returns for in-warranty repairs may be rejected or subject to an inspection and handling charge of $75 plus any repair and all transportation charges.

The warranty is expressly in lieu of all other warranties, expressed or implied, including, and without limitation, any implied warranty or merchantability or fitness for a particular purpose, and/or any other obligation or liability on the part of Energy Technologies Inc. The sole exclusive remedy for breach of any warranty, expressed or implied, concerning ETI’s products and the only obligation of ETI hereunder, shall be the repair or replacement of defective equipment, components, or parts, or, at ETI’s option, the refund of the purchase price or substitution with a new replacement product. ETI shall in no way be responsible for any consequential damages, of any kind, or nature whatsoever, resulting from the breach of any warranty.

Tell Us About Your Needs

*(denotes required field)
prime contractors

Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466

// code for product search below