The post ETI0003-1021 Rugged Rackmount Power Distribution Unit appeared first on Rugged Systems.
]]>The LEDarrays keep the operator informed as to the unit’s status. An alarm will flash its respective LED until acknowledged. Once the alarm reset is pressed, the LEDwill remain on steady until the alarm is cleared. The intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battleshort override. Each load can have an external interlock to turn off power to equipment when it is not fully engaged in the rack or becomes overheated. The rack may be equipped with both a thermal warning and a thermal shutdown sensor that the PDU uses to alarm and shut down all the loads to avoid damage or thermal runaway. A Battleshort signal will override both the thermal and interlock signals. An external CPU Fail or auxiliary alarm signal can also be brought in to annunciate. The display and control panel can be mounted remotely in the rack, or on the keyboard console, or on the unit front panel with only a logic-level cable connection. The high-intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. The double pole input breaker provides overload and short circuit protection for the connected loads. The optional Emergency Power Off (EPO) function can remotely open the input circuit breaker. Each load is controlled by a double pole solidstate relay avoiding accidental operation due to shock or vibration. The elapsed time hour meter tracks the rack equipment operation for maintenance.
The rear panel provides locking connectors for the input power, output power, alarm and control signals. Appropriate jumper plugs are available for options not used in a particular rack system.
Overall, the Rugged Power product line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
The post ETI0003-1021 Rugged Rackmount Power Distribution Unit appeared first on Rugged Systems.
]]>The post ETI0003-1013 Rugged Rackmount Power Distribution Unit appeared first on Rugged Systems.
]]>The LEDarrays keep the operator informed as to the unit’s status. An alarm will flash its respective LED until acknowledged. Once the alarm reset is pressed, the LEDwill remain on steady until the alarm is cleared. The intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battleshort override. Each load can have an external interlock to turn off power to equipment when it is not fully engaged in the rack or becomes overheated. The rack may be equipped with both a thermal warning and a thermal shutdown sensor that the PDU uses to alarm and shut down all the loads to avoid damage or thermal runaway. A Battleshort signal will override both the thermal and interlock signals. An external CPU Fail or auxiliary alarm signal can also be brought in to annunciate. The display and control panel can be mounted remotely in the rack, or on the keyboard console, or on the unit front panel with only a logic-level cable connection. The high-intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. The double pole input breaker provides overload and short circuit protection for the connected loads. The optional Emergency Power Off (EPO) function can remotely open the input circuit breaker. Each load is controlled by a double pole solidstate relay avoiding accidental operation due to shock or vibration. The elapsed time hour meter tracks the rack equipment operation for maintenance.
The rear panel provides locking connectors for the input power, output power, alarm and control signals. Appropriate jumper plugs are available for options not used in a particular rack system.
Overall, the Rugged Power product line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
The post ETI0003-1013 Rugged Rackmount Power Distribution Unit appeared first on Rugged Systems.
]]>The post ETI0001-2255A3 power supply appeared first on Rugged Systems.
]]>If you have inquiries about this product, please use the field below.
This series of products includes:
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-2255A3 power supply appeared first on Rugged Systems.
]]>The post ETI0001-2255AA rugged ups appeared first on Rugged Systems.
]]>If you have inquiries about this product, please use the field below.
This series of products includes:
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-2255AA rugged ups appeared first on Rugged Systems.
]]>Mil Spec UPS Rugged Rackmount
The post ETI0001-2249AA, 4 kVA UPS appeared first on Rugged Systems.
]]>If you have inquiries about this product, please use the field below.
This series consists of both of these units:
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-2249AA, 4 kVA UPS appeared first on Rugged Systems.
]]>The post ETI0001-1260A5 4.0 kVA UPS & Frequency Converter appeared first on Rugged Systems.
]]>The heavy-duty chassis, occupying only 3U (5.25″) of rack space and 23.5″ depth, has rounded metal corners and rugged front-mounted handles, aiding in safe handling. Companion 2U (3.5″ high) Battery Expansion Modules are designed to be daisy-chained to bring up the backup time in the typical configuration. In the typical application, the base UPS unit and up to four Battery Modules are mounted in the lower underside of a rack or cart. Both module chassis is constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra-low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60-hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for systems or locations where phase references and grounding are not consistent. For scenarios that need hospital-grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The rear panel provides a locking connector for the input power and NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high-capacity stainless steel ball-bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The “ETI0001-1260A5” has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further.
This series of products includes:
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1260A5 4.0 kVA UPS & Frequency Converter appeared first on Rugged Systems.
]]>The post ETI0001-1260AA 4.0 kVA UPS & Frequency Converter appeared first on Rugged Systems.
]]>The heavy-duty chassis, occupying only 3U (5.25″) of rack space and 23.5″ depth, has rounded metal corners and rugged front mounted handles, aiding in safe handling. Companion 2U (3.5″ high) Battery Expansion Modules are designed to be daisy-chained to bring up the backup time in the typical configuration. In the typical application, the base UPS unit and up to four Battery Modules are mounted in the lower underside of a rack or cart. Both module chassis are constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for systems or locations where phase references and grounding are not consistent. For scenarios that need hospital-grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The rear panel provides a locking connector for the input power and NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The “ETI0001-1260AA” has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further.
This series of products includes:
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1260AA 4.0 kVA UPS & Frequency Converter appeared first on Rugged Systems.
]]>The post ETI0001-1260AJ 4.0 kVA UPS & Frequency Converter appeared first on Rugged Systems.
]]>The heavy-duty chassis, occupying only 3U (5.25″) of rack space and 23.5″ depth, has rounded metal corners and rugged front-mounted handles, aiding in safe handling. Companion 2U (3.5″ high) Battery Expansion Modules are designed to be daisy-chained to bring up the backup time in the typical configuration. In the typical application, the base UPS unit and up to four Battery Modules are mounted in the lower underside of a rack or cart. Both module chassis is constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra-low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60-hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for systems or locations where phase references and grounding are not consistent. For scenarios that need hospital-grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The rear panel provides a locking connector for the input power and NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The “ETI0001-1260AJ” has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further.
This series of products includes:
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1260AJ 4.0 kVA UPS & Frequency Converter appeared first on Rugged Systems.
]]>The post ETI0001-1428A1 UPS, with Intelligent PDU appeared first on Rugged Systems.
]]>For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
There are the available models. Contact us for more information:
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1428A1 UPS, with Intelligent PDU appeared first on Rugged Systems.
]]>The post ETI0001-1429 UPS, with Intelligent PDU appeared first on Rugged Systems.
]]>The heavy-duty chassis occupies only 3U (5.25″) of Rackspace while delivering up to 2400 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. The optional mounting kits include flanges that allow the use of TAC-4 style shock isolation pins and bushings used in some racks.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This unique circuit allows this UPS to deliver up to 20 amps to the load, while utilizing less than 20 amps from the source, thus maximizing the use of existing circuits.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battleshort override. The display and control panel can be mounted remotely in the rack or on the front panel with only a logic-level cable connection. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high-capacity stainless steel ball-bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of the standard or extra battery modules without having to shut the unit down. The batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials. For more information, see the Battery Technology section. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
See the Power Distribution Units section for a listing of stand-alone PDUs. See the N3 Series UPS section for UPS without the integrated PDU and remote control.
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction
The post ETI0001-1429 UPS, with Intelligent PDU appeared first on Rugged Systems.
]]>