Warning: Trying to access array offset on value of type bool in /home/ruggedups/public_html/wp-content/themes/rugged-systems/divi-children-engine/functions/divi-mod-functions.php on line 75

Warning: Cannot modify header information - headers already sent by (output started at /home/ruggedups/public_html/wp-content/themes/rugged-systems/divi-children-engine/functions/divi-mod-functions.php:75) in /home/ruggedups/public_html/wp-includes/feed-rss2.php on line 8
N1 Archives - Rugged Systems https://ruggedups.com/product-tag/n1/ Rugged Power - Global Solutions Fri, 24 Jan 2025 00:50:15 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.5 https://ruggedups.com/wp-content/uploads/2020/07/cropped-header-32x32.jpg N1 Archives - Rugged Systems https://ruggedups.com/product-tag/n1/ 32 32 ETI0001-1060AC, 1000 VA Rugged Rackmount UPS https://ruggedups.com/product/eti0001-1060ac-1000-va-rugged-rackmount-ups/ Tue, 09 Mar 2021 15:53:53 +0000 http://ruggedups.com/?post_type=product&p=1488 Part #: ETI0001-1060
NSN: 6130-01-628-1653
  • 85-270 VAC, 46-70 Hz Input, 230 VAC, 50 Hz Output
  • 1000 VA Rugged Rack Mount, Modular Power System

The post ETI0001-1060AC, 1000 VA Rugged Rackmount UPS appeared first on Rugged Systems.

]]>
85-270 VAC, 46-70 Hz Input, 230 VAC
50 Hz Output 1000 VA Rugged Rack Mount
Modular Power System

Standard Product: Condor / Egypt

The field-proven Rugged Power™ UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size, and lightweight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1060AC was initially designed for Condor for use in Egypt’s hostile environment.

The heavy-duty chassis occupies only 3U (5.25″) of rack space while delivering up to 1000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

The internal shielded input transformer provides galvanic isolation with provisions for auto ranging domestic (115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. For field-deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high-capacity stainless steel ball-bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate airflow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials. For more information, see the Battery Technology section.

The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60-hertz power. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

See the Power Distribution Units section for a listing of stand-alone PDUs. See the N5 Series for a version of this UPS with an integrated PDU and remote control.

The Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.

Also available is the: ET10001-1060

The post ETI0001-1060AC, 1000 VA Rugged Rackmount UPS appeared first on Rugged Systems.

]]>
ETI0001-1240 Series, 1000 VA and Frequency Converter for USAF https://ruggedups.com/product/eti0001-1240-1000-va-and-frequency-converter/ Wed, 30 Sep 2020 18:06:31 +0000 http://ruggedups.com/?post_type=product&p=958 Rugged Mil Spec® Rack or Fixed Mount
1000 VA UPS
 and Frequency Converter
Used in Medical Applications
  • US Air Force ECMO Medical Patient Cart Application
  • 1.0 kVA Mil Spec UPS and Frequency Converter
  • Rugged Rack or Fixed Mount Unit
  • Reduced Depth
  • Multiple Battery Modules for up to 4 Hours of Battery Backup between Locations
  • Accepts both Aircraft Power and Commercial Power

The post ETI0001-1240 Series, 1000 VA and Frequency Converter for USAF appeared first on Rugged Systems.

]]>
The field proven Airborne Power®  UPS line is ideally suited for military, industrial, medical and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The”ETI0001-1240″ is being used by the US Air Force ECMO Cart project because of their stringent performance and reliability requirements.

The heavy-duty chassis, occupying only  3U (5.25″ high) of rack space and 18.5″ depth, has rounded metal corners and rugged handles front and rear, aiding in safe handling. The companion 2U(3.5″ high) Battery Expansion Modules are designed to be daisy chained to bring the backup time to 4 hours in the typical configuration.  In the typical ECMO Cart application, the base UPS unit and up to four Battery Modules are mounted in the lower underside section of the patient cart. Both module chassis are constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for systems or locations where phase references and grounding are not consistent.  For scenarios that need hospital grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides a locking connector for the input power and six hospital grade NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The “ETI0001-1240” has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further. The optional Battery Charger/Conditioner (which has aircraft and global input capability) is used to maintain the spare Battery Modules in ready condition at all times. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

For other versions of this product, inquire for information on these model numbers:

  • ETI0001-1240A1 (Model #: ETI0001-N3-1.0) w remote on/off
  • ETI0001-1240A2:  00 Watt UPS with Universal AC Input, aka ETI0001-1240AZ  (Model #: ETI0001-N3-1.0) w remote on/off, Schlumberger Part #: 100629876
  • ETI0001-1240AA (Model #: ETI0001-N3U-KI-1.0) w 461E surface, Shock & Vibration
  • ETI0001-1240AB (Model #: ETI0001-N3U-KI-1.0) w 461E surface, Shock & Vibration, without batteries
  • ETI0001-1240AC (Model #: ETI0001-N3U-KIF4-1.0) w 461E surface, Shock & Vibration with SNMP but no battery
  • ETI0001-1240AD (Model #: ETI0001-N3-1.0) w 461E surface, Shock & Vibration & remote on/off switch, Steel Chassis
  • ETI0001-1240AE (Model #: ETI0001-N3-1.0) w 461E surface, Shock & Vibration & remote on/off switch, Aluminum Chassis
  • ETI0001-1240AF (Model #: ETI0001-N3U-KI/2.0)
  • See the N5 Series ETI0001-1479 for a version of this UPS with an integrated PDU and remote control.
  • See the Power Distribution Units section for a listing of stand alone PDUs.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

The post ETI0001-1240 Series, 1000 VA and Frequency Converter for USAF appeared first on Rugged Systems.

]]>
ETI0001-1237AA, 2000 VA TAC-4 UPS w battery https://ruggedups.com/product/eti0001-1237aa-2000-va-ultra-rugged-ups-w-battery/ Tue, 29 Sep 2020 18:09:30 +0000 http://ruggedups.com/?post_type=product&p=955 Ultra Rugged Mil Spec® 2000 VA UPS
  • Military Power® Mil Spec Configuration
  • Rugged Rack Mount with Global Isolated Input
  • Input PFC, Battleshort Override and Elapsed Time Indicator
  • Front Access Hot Swappable Battery Module

The post ETI0001-1237AA, 2000 VA TAC-4 UPS w battery appeared first on Rugged Systems.

]]>
The field proven Military Power UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design.These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments.The ETI0001-1237AA was specifically designed to mount in the TAC-4 racks and interface with either the TAC-4 PDU or any of numerous ETI PDUs.

The heavy-duty chassis occupies only 5.25″ (3U) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional heavy-duty rack slides provide easy installation and removal of the unit with full extension. Rear shock isolation/alignment bushings off load the slides when the unit is fully engaged.

The internal shielded input transformer provides galvanic isolation with provisions for both domestic(115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. The input voltage selection allows inputting either 115 VAC or 230 VAC without having to open the UPS enclosure. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to clean, uninterruptible 60 hertz power. Optionally, 46-440 hertz input as well either 50 or 400 hertz outputs are available.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The front panel also provides easy access to both the AC Input and Battery Input fuses. Coupled with the adjacent spare fuses, MTTR is reduced to less than 15 minutes.

The internal intelligent thermal sensors provide two stage monitoring of unit temperatures,with both local and remote Battle short override capability of thermal shutdown. Battle short can be engaged via the front panel control, via a remote contact input or via a software command. When in Battle short, an audible alarm is sounded and an indicator is lit. The high intensity audible alarm can be heard in high noise environments and includes an audible enable/disable switch.

All controls and protective devices are brought to the front and rear panels with critical switches or circuit breakers having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

The rear panel provides locking connectors for the input and output power with various optional configurations available. This reverse air flow version draws air through the front and exhausts out the rear vent into the rack. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. Clips on the rear panel hold additional spare fuses for ready access.

The ETI0001-1237AA has the added benefit of having a field replaceable battery via front draw out battery module. The battery is a true hot-swappable module and does not require going to bypass like competing units. Even with this battery module removed, this UPS can continue to operate as an electronic power conditioner and frequency converter, providing clean, well regulated, sinusoidal power to the load. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials for added safety. For more information, see the Battery Technology section.

For more information:

  • ETI0001-1237 for the original version of this unit
  • ETI0001-1237AD also available
  • ETI0001-1237AF also available
  • The two status D shell connectors provide both a contact and serial interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
  • See the Power Distribution Units section for a listing of stand alone PDUs.
  • See the N5 Series for a version of this UPS with an integrated PDU and remote control.
  • For a side by side comparison of ETI0001-1237 vs. ETI0001-1237AA, click here.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

The post ETI0001-1237AA, 2000 VA TAC-4 UPS w battery appeared first on Rugged Systems.

]]>
ETI0001-1254, 2000 VA UPS & Frequency Converter for AN/TPS-59 https://ruggedups.com/product/eti0001-1254-2000-va-ups-frequency-converter/ Thu, 17 Sep 2020 17:25:50 +0000 http://ruggedups.com/?post_type=product&p=926 Rugged Mil Spec® Rack or Fixed Mount
2000 VA UPS
 and Frequency Converter

US Marine Corps.Radar AN/TPS-59, LockheedMartin
2.0 kVA Mil Spec UPS and Frequency Converter Rugged Rack or Fixed Mount Unit w/ Reduced Depth and Removable Battery Module

The post ETI0001-1254, 2000 VA UPS & Frequency Converter for AN/TPS-59 appeared first on Rugged Systems.

]]>
The field proven Military Power® UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The”
ETI0001-1254″ is being used by the Marine Corps. AN/TPS-59 Radar Upgrade project because of their stringent performance and reliability requirements.

The heavy-duty chassis,occupying only 7″ (4U) of rack space and 18.5″ depth, has rounded metal corners and rugged handles front and rear, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean,uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The ”
ETI0001-1254″ has the added benefit of having afield replaceable battery via a rear draw out battery module. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.

Overall, the Military Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

The post ETI0001-1254, 2000 VA UPS & Frequency Converter for AN/TPS-59 appeared first on Rugged Systems.

]]>
ETI0001-1237, 2000 VAUS Navy, HP TAC-4, TAC-JW, Rackmount UPS https://ruggedups.com/product/eti0001-1237-2000-va-rugged-rackmount-ups/ Thu, 10 Sep 2020 17:38:24 +0000 http://ruggedups.com/?post_type=product&p=851 ETI Model: ETI0001-S1R-KII/2.0

NSN: 6130-01-462-8656
or 6130-01-470-8743
or 6130-01-470-1368
Ultra Rugged Mil Spec
® 2000 VA Rackmount Tactical UPS

  • Lockheed Martin P/N: 20534121G01
  • US Navy P/N: 72206
  • TAC-4 P/N: S5257-00001
  • Agilent (HP) P/N: FCO-ETI0001-S1R

Direct Replacement for:

  • NSN: 6130-01-530-3056 or 6130-01-523-4761
  • Milpower Source P/N:M-120BA-1A
  • AP Labs P/N: 12928
  • Naval Air Systems Command P/N: 3686AS2946-1

Standard S1R Configuration

Compatible w/ all ATWCS, TTWCS, Tomahawk, TAC-4 and TAC-JW Systems

Military Power® Mil Spec Configuration, 2000 VA UPS

Global Isolated Input and Input PFC

The post ETI0001-1237, 2000 VAUS Navy, HP TAC-4, TAC-JW, Rackmount UPS appeared first on Rugged Systems.

]]>
The field proven TEST TEST Military Power® UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design.These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1237 was specifically designed to mount in the TAC-4 racks and interface with either the TAC-4 PDU or any of numerous ETI PDUs.

The heavy-duty chassis occupies only 5.25″ (3U) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional heavy-duty rack slides provide easy installation and removal of the unit with full extension. Rear shock isolation/alignment bushings off load the slides when the unit is fully engaged.

The internal shielded input transformer provides galvanic isolation with provisions for both domestic(115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. The input voltage selection allows inputting either 115 VAC or 230 VAC without having to open the UPS enclosure. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to clean, uninterruptible 60 hertz power. Optionally, 46-440 hertz input as well either 50 or 400 hertz outputs are available.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions.All controls and protective devices are brought to front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation.

The rear panel provides locking connectors for the input and output power with various optional configurations available. This reverse air flow version draws air through the front and exhausts out the rear vent into the rack. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The two status D shell connectors provide both a contact and serial interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

For more information:

  • ETI0001-1237AA for a new version of this unit with front access, hot swappable, drawout battery module, plus battleshort and elapsed time features.
  • ETI0001-1237AD also available
  • ETI0001-1237AF also available
  • For a side by side comparison of ETI0001-1237 vs. ETI0001-1237AA.
  • See the Power Distribution Units section for a listing of stand alone PDUs.
  • See the N5 Series ETI0001-1437 for a version of this UPS with an integrated PDU and remote control.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

The post ETI0001-1237, 2000 VAUS Navy, HP TAC-4, TAC-JW, Rackmount UPS appeared first on Rugged Systems.

]]>
ETI0001-1060, 1000 VA Rugged Rackmount UPS https://ruggedups.com/product/eti0001-1060-1000-va-rugged-rackmount-ups/ Thu, 30 Jul 2020 17:18:48 +0000 http://ruggedups.com/?post_type=product&p=565
  • Part #: ETI0001-1060
  • 85-270 VAC, 46-70 Hz Input, 230 VAC, 50 Hz Output
  • 1000 VA Rugged Rack Mount, Modular Power System
  • The post ETI0001-1060, 1000 VA Rugged Rackmount UPS appeared first on Rugged Systems.

    ]]>
    85-270 VAC, 46-70 Hz Input, 230 VAC, 50 Hz Output 1000 VA Rugged Rack Mount, Modular Power System

    Standard Product: Condor / Egypt

    The field proven Rugged Power™ UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1060was initially designed for Condor for use in Egypt’s hostile environment.

    The heavy-duty chassis occupies only 3U (5.25″) of rack space while delivering up to 1000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

    The internal shielded input transformer provides galvanic isolation with provisions for autoranging domestic (115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. For field deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

    The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

    The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section.

    The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an  interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

    See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series for a version of this UPS with an integrated PDU and remote control.

    The Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

    Also available is the: ET10001-1060AC · NSN: 6130-01-628-1653

    The post ETI0001-1060, 1000 VA Rugged Rackmount UPS appeared first on Rugged Systems.

    ]]>
    ETI0001-1058, 2000 VA Rugged Rackmount UPS for US Navy Arleigh Burke-class destroyers https://ruggedups.com/product/eti0001-1058-2000-va-rugged-rackmount-ups-for-naval-destroyers/ Thu, 30 Jul 2020 17:06:41 +0000 http://ruggedups.com/?post_type=product&p=564
  • Part #: ETI0001-1058
  • Model: ETI0001-N1A13-I/2.0
  • NSN: 6130-01-523-2028
  • L-3 / Henschel P/N: G-4490
  • L-3 / Henschel P/N: 10-2226-94 REV F ITEM NO. 44
  • The post ETI0001-1058, 2000 VA Rugged Rackmount UPS for US Navy Arleigh Burke-class destroyers appeared first on Rugged Systems.

    ]]>
    Rugged COTS 2000 VA Rackmount UPS

    L-3 / Henschel P/N: G-4490 NSN: 6130-01-523-2028

    L-3 / Henschel Standard Product Standard N1 Configuration Rugged Power Isolated UPS Modular Power System

    The field proven Rugged Power™ UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1058” was initially designed for US Navy shipboard applications, becoming the standard for several programs.

    The heavy-duty chassis occupies only 3U (5.25″) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

    The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. For field deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

    The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

    The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high  capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. This reverse air flow version draws from the front and exhaust air is diverted out the rear vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section.

    The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an  interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

    See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series for a version of this UPS with an integrated PDU and remote control.

    The Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

    Also available in this series: ETI0001-1058AA

    The post ETI0001-1058, 2000 VA Rugged Rackmount UPS for US Navy Arleigh Burke-class destroyers appeared first on Rugged Systems.

    ]]>
    ETI0001-1057, 3000 VA Rugged Rackmount UPS w Backup https://ruggedups.com/product/eti0001-1057-3000-va-rugged-rackmount-ups-w-backup/ Wed, 29 Jul 2020 15:58:25 +0000 http://ruggedups.com/?post_type=product&p=562
  • Part #: ETI0001-1057
  • 220 VAC, 50 Hz Input/Output Isolated UPS
  • 3000 VA Rugged Rack Mount, Modular Power System
  • 45 Minutes of Battery Backup
  • Applied Data Standard Product

    The post ETI0001-1057, 3000 VA Rugged Rackmount UPS w Backup appeared first on Rugged Systems.

    ]]>
    Overseas 220 VAC 50 Hz Input/Output Isolated UPS 3000 VA Rugged Rack Mount, Modular Power System

    45 minutes of Battery Backup Standard Product: Applied Data

    The field proven Rugged Power™ UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1057″was initially designed for Applied Data overseas applications, becoming the standard for several programs.

    Each heavy-duty chassis occupies a minimum of rack space while delivering up to 3000 VA of clean, uninterruptible power continuously. The rounded metal corners and rugged handles, aidin safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

    The internal shielded input transformer provides galvanic isolation with provisions for international (220 VAC, OCONUS) input voltage.

    The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

    The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section.

    The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an  interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

    See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series for a version of this UPS with an integrated PDU and remote control.

    The Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

    Also available:

    • ETI0001-1057AA 
    • ETI0001-1057A3

    The post ETI0001-1057, 3000 VA Rugged Rackmount UPS w Backup appeared first on Rugged Systems.

    ]]>
    ETI0001-1051, 1000 VA Rugged Rackmount UPS w 4 Hr Backup https://ruggedups.com/product/eti0001-1051-1000-va-rugged-rackmount-ups-w-battery_backup/ Wed, 29 Jul 2020 15:44:45 +0000 http://ruggedups.com/?post_type=product&p=561
  • Part #: ETI0001-1051
  • Rugged COTS 1000 VA Rackmount UPS
  • Autoranging Input allows the Unit to be  used worldwide
  • Four (4) Hours of Battery Backup
  • Mobile Casters Base
  • US Navy SPAWAR Standard Product

    The post ETI0001-1051, 1000 VA Rugged Rackmount UPS w 4 Hr Backup appeared first on Rugged Systems.

    ]]>
    Standard US Army Product Standard N1 Configuration, Rugged Power Isolated UPS 1000 VA Rugged Rack Mount, Modular Power System

    Autoranging Input Allow the Unit to be Used Worldwide Four (4) Hours of BatteryBackup w/ Mobile Casters Base

    The field proven Rugged Power™ UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1051” was initially designed for US Army applications, becoming the standard for several programs.

    The heavy-duty chassis with casters occupies a minimum of space while delivering up to 1000 VA of clean, uninterruptible power. The UPS plus extended battery module provide over 4 hours of backup. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.

    The internal shielded input transformer provides galvanic isolation with autoranging for both domestic (115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. For field deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

    The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

    The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section.

    The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an  interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

    See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series for a version of this UPS with an integrated PDU and remote control.

    The Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

    The post ETI0001-1051, 1000 VA Rugged Rackmount UPS w 4 Hr Backup appeared first on Rugged Systems.

    ]]>
    ETI0001-1040, 2000 VA Rugged Rackmount UPS https://ruggedups.com/product/eti0001-1040-2000-va-rugged-rackmount-ups/ Wed, 29 Jul 2020 15:36:26 +0000 http://ruggedups.com/?post_type=product&p=560 US Navy SPAWAR Standard Product Standard N1 Configuration, Rugged Power Isolated UPS 2000 VA Rugged Rack Mount, Modular Power System Eight CPC Locking Outputs

    NSN: 6130-01-500-5983

    • Alternate P/N: 0205020G1
    • Model: ETI0001-N1RA7-I/2.0
    • Rugged COTS 2000 VA Rackmount UPS

    US Navy SPAWAR Standard Product

    The post ETI0001-1040, 2000 VA Rugged Rackmount UPS appeared first on Rugged Systems.

    ]]>
    The field-proven Rugged Power™ UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and lightweight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1040” was initially designed for US Navy shipboard applications, becoming the standard for several programs.

    The heavy-duty chassis occupies only 3U (5.25″) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

    The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. For field-deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

    The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

    The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high-capacity stainless steel ball-bearing fan provide added protection in both controlled and hostile environments. This reverse air flow version draws from the front and exhaust air is diverted out the rear vent, with alternate airflow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials. For more information, see the Battery Technology section.

    The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

    See the Power Distribution Units section for a listing of stand-alone PDUs. See the N5 Series for a version of this UPS with an integrated PDU and remote control.

    The Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.

    The post ETI0001-1040, 2000 VA Rugged Rackmount UPS appeared first on Rugged Systems.

    ]]>