The post ETI0001-2295 PowerStation 1kVA UPS w/ PDU / 120VAC input-output /500 Watts appeared first on Rugged Systems.
]]>The heavy-duty chassis, occupying only 6.967″ (4U) of rack space and 15.68″ depth, has rounded metal corners and rugged handles right and left, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (120 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to clean, uninterruptible 60-hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The right panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. Removable and washable air filters and high-capacity stainless steel ball-bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the rear vent, with alternate airflow directions optional. The batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
See the Power Distribution Units section for a listing of stand-alone PDUs. See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.
Overall, the PowerStation line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-2295 PowerStation 1kVA UPS w/ PDU / 120VAC input-output /500 Watts appeared first on Rugged Systems.
]]>The post ETI0001-2275 Rack, Floor, or Shelf Mounted 2000 VA UPS & Frequency Converter appeared first on Rugged Systems.
]]>The heavy-duty chassis, occupying only 6.967″ (4U) of rack space and 15.68″ depth, has rounded metal corners and rugged handles right and left, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (120 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to clean, uninterruptible 60-hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The right panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. Removable and washable air filters and high-capacity stainless steel ball-bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the rear vent, with alternate airflow directions optional. The batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
See the Power Distribution Units section for a listing of stand-alone PDUs. See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.
Overall, the PowerStation line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-2275 Rack, Floor, or Shelf Mounted 2000 VA UPS & Frequency Converter appeared first on Rugged Systems.
]]>The post ETI0001-1473AF, 2000 VA, with integrated Power Conditioner and PDU appeared first on Rugged Systems.
]]>The heavy-duty chassis, occupying only 5.25”(3U) for the electronics and 3.5″ (2U) for the optional battery module by 22” depth, delivers up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis.
The standard version accepts domestic voltages from 85-135 VAC at full load. At loads less than full load, the input voltage can be even lower. The optional global input version has auto-ranging from 85-270 VAC (CONUS and OCONUS) utilizing an internal input transformer. When ordering the global version, the input circuit breaker and the galvanic isolation transformer provide a double pole isolated source for overseas locations where phase references and grounding are not consistent.
The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 or 50 hertz power switch selectable. The unit can also be ordered with 46-440 hertz input. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The ETI0001-1473AA has the added benefit of having an internally redundant 24 VDC DC power source output.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The front and rear panels also provide easy access to both the AC Input and Battery Input fuses. Coupled with the adjacent spare fuses, MTTR is reduced to less than 15 minutes.
The internal intelligent thermal sensors provide two-stage monitoring of unit temperatures, with both local and remote Inhibit Over Temperature (INHIBIT OVRTMP) capability of thermal shutdown. INHIBIT OVRTMP can be engaged via the front panel control, via a remote contact input or via a software command. When in INHIBIT OVRTMP, an audible alarm is sounded and an indicator is lit. The high-intensity audible alarm can be heard in high noise environments and includes an audible enable/disable/reset switch and an adjustable vane to control the sound level.
All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety. Ten push/pull circuit breakers provide both circuit protection and manual controls. Both the input and load circuit breakers are shock-rated to over 100 Gs. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. This unit draws air through the front air filter and exhausts out the rear vent into the rack. This allows the unit to be used in either negative or neutral pressure racks. The stainless steel ball-bearing fan is a special extra quiet version to keep the unit’s overall audible level below 44 dB.
The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The UPS Remote Control and PDU Remote Control connectors provide an interface to optional remote display/control panels. The RJ45 LAN port provides an SNMP/HTTP interface for various UPS parameters and control of the load outputs. Internal software functions include the ability to Sequence Loads of Startup and to Shed Loads for either Overload or Over temperature or to lengthen battery run time (when used with battery modules). These functions follow user-defined priority lists and schedules.
The batteries in the optional battery modules are maintenance-free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information:
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1473AF, 2000 VA, with integrated Power Conditioner and PDU appeared first on Rugged Systems.
]]>The post ETI0001-1473AD, 2000 VA, with integrated Power Conditioner and PDU appeared first on Rugged Systems.
]]>The heavy-duty chassis, occupying only 5.25”(3U) for the electronics and 3.5″ (2U) for the optional battery module by 22” depth, delivers up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis.
The standard version accepts domestic voltages from 85-135 VAC at full load. At loads less than full load, the input voltage can be even lower. The optional global input version has auto-ranging from 85-270 VAC (CONUS and OCONUS) utilizing an internal input transformer. When ordering the global version, the input circuit breaker and the galvanic isolation transformer provide a double pole isolated source for overseas locations where phase references and grounding are not consistent.
The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 or 50 hertz power switch selectable. The unit can also be ordered with 46-440 hertz input. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The ETI0001-1473AA has the added benefit of having an internally redundant 24 VDC DC power source output.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The front and rear panels also provide easy access to both the AC Input and Battery Input fuses. Coupled with the adjacent spare fuses, MTTR is reduced to less than 15 minutes.
The internal intelligent thermal sensors provide two-stage monitoring of unit temperatures, with both local and remote Inhibit Over Temperature (INHIBIT OVRTMP) capability of thermal shutdown. INHIBIT OVRTMP can be engaged via the front panel control, via a remote contact input or via a software command. When in INHIBIT OVRTMP, an audible alarm is sounded and an indicator is lit. The high-intensity audible alarm can be heard in high noise environments and includes an audible enable/disable/reset switch and an adjustable vane to control the sound level.
All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety. Ten push/pull circuit breakers provide both circuit protection and manual controls. Both the input and load circuit breakers are shock-rated to over 100 Gs. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. This unit draws air through the front air filter and exhausts out the rear vent into the rack. This allows the unit to be used in either negative or neutral pressure racks. The stainless steel ball-bearing fan is a special extra quiet version to keep the unit’s overall audible level below 44 dB.
The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The UPS Remote Control and PDU Remote Control connectors provide an interface to optional remote display/control panels. The RJ45 LAN port provides an SNMP/HTTP interface for various UPS parameters and control of the load outputs. Internal software functions include the ability to Sequence Loads of Startup and to Shed Loads for either Overload or Over temperature or to lengthen battery run time (when used with battery modules). These functions follow user-defined priority lists and schedules.
The batteries in the optional battery modules are maintenance-free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information:
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1473AD, 2000 VA, with integrated Power Conditioner and PDU appeared first on Rugged Systems.
]]>University of Texas / Navy Rugged Power™ Mil Spec N5Configuration
2000 VA Rugged Rack MountIsolated UPS w/ Integrated
6 Circuit, 2 Pole, Intelligent, Solidstate Power Distribution Unit
With Drip Proof Front Panel, Shallow Depth, Removable Battery
The post ETI0001-1483, 2000 VA UPS, with Intelligent PDU for University of Texas appeared first on Rugged Systems.
]]>The heavy-duty chassis occupies only 4U (7.0”) of rack space and is only 18.5″ deep making it suitable for shallow racks as found on submarines. The front panel is sealed meeting the Navy drip-proof requirements. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis. These units can be mounted horizontally or vertically.
The internal shielded input transformer provides galvanic isolation with provisions for both domestic(115 VAC, CONUS) and optional auto-ranging international input voltages (85-270 VAC,OCONUS). The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60-hertz power. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The high-intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battle-short override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are unique allowing the use of either standard NEMA 5-15P plugs or MS threaded metal shell connectors. This unit draws air through the rear air filter and exhausts out the side vents into the rack. This allows the unit to be used in either positive, negative or neutral pressure racks. The removable and washable metal screen air filters and high capacity stainless steel ball-bearing fans provide added protection in both controlled and hostile environments. The
ETI0001-1482 has the added benefit of having afield replaceable battery via a rear draw-out battery module. The batteries are maintenance-free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information see the Power Distribution Units section for a listing of stand alone PDUs
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1483, 2000 VA UPS, with Intelligent PDU for University of Texas appeared first on Rugged Systems.
]]>L3 Comm / Navy Military Power® Mil Spec N5Configuration
2000 VA Rugged Rack Mount Isolated UPS w/ Integrated
6 Circuit, 2 Pole, Intelligent, Solidstate Power Distribution Unit
With Drip Proof Front Panel, Shallow Depth, Removable Battery
The post ETI0001-1482, 2000 VA UPS, with Intelligent PDU for L3 Comm appeared first on Rugged Systems.
]]>The heavy-duty chassis occupies only 4U (7.0”) of rack space and is only 18.5″ deep making it suitable for shallow racks as found on submarines. The front panel is sealed meeting the Navy drip proof requirements. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis. These units can be mounted horizontally or vertically.
The internal shielded input transformer provides galvanic isolation with provisions for both domestic(115 VAC, CONUS) and optional auto-ranging international input voltages (85-270 VAC,OCONUS). The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battle-short override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are unique allowing the use of either standard NEMA 5-15P plugs or MS threaded metal shell connectors. This unit draws air through the rear air filter and exhausts out the side vents into the rack. This allows the unit to be used in either positive, negative or neutral pressure racks. The removable and washable metal screen air filters and high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The
ETI0001-1482 has the added benefit of having afield replaceable battery via a rear draw-out battery module. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information see the Power Distribution Units section for a listing of stand alone PDUs
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1482, 2000 VA UPS, with Intelligent PDU for L3 Comm appeared first on Rugged Systems.
]]>NSN 6130-01-618-1189
P/N: 7190789+000
Standard: US Navy Q-70 Tactical Open Systems, E-CDWS, L-3 COMMUNICATIONS
Rugged Power™ Isolated UPS
12" Depth
PFC Input
Intelligent PDU
Remote Shutdown
Auxiliary DC Output
The post ETI0001-1474 Series, 2000 VA UPS, with Intelligent PDU for Navy L-3 appeared first on Rugged Systems.
]]>The heavy-duty chassis occupies only 3U (5.25”) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. Rear shock isolation/alignment bushings off load the slides when the unit is fully engaged.
The internal shielded input transformer provides galvanic isolation with provisions for both domestic(115 VAC, CONUS) and optional auto-ranging international input voltages (230 VAC,OCONUS). Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments.. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battle-short override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are standard NEMA 5-15R receptacles with stainless steel cable restraints. This reverse air flow version draws air through the front and exhausts out the rear vent into the rack. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information see the Power Distribution Units section for a listing of stand alone PDUs
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1474 Series, 2000 VA UPS, with Intelligent PDU for Navy L-3 appeared first on Rugged Systems.
]]>Standard: US Navy Q-70 Tactical Open Systems, E-CDWS
Rugged Power™ Isolated UPS
12" Depth
PFC Input
Intelligent PDU
Remote Shutdown
Auxiliary DC Output
The post ETI0001-1450 Series, 2000 VA UPS, with Intelligent PDU for Navy Q-70 appeared first on Rugged Systems.
]]>The heavy-duty chassis occupies only4U (7”) for the electronics module and 2U (3.5″) for the battery module of rack space by an ultra shallow 12″ deep. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optional international (230 VAC, OCONUS) input voltages. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battle-short override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. The removable and washable intake air filters and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. This version draws air through the rear and exhausts out the front vents. The external battery connector allows the safe and easy addition of the standard or extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information see the Power Distribution Units section for a listing of stand alone PDUs
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1450 Series, 2000 VA UPS, with Intelligent PDU for Navy Q-70 appeared first on Rugged Systems.
]]>US Navy AN/SQQ89(V)15
Standard Product: Integrated Surface Ship ASW Combat System
Rugged Power™ Mil Spec N5 Configuration
Isolated UPS, 2000 VA Rugged Rack Mount UPS w/ Integrated
6 Circuit, 2 Pole, Intelligent, Solid-state Power Distribution Unit
NSN: 6130-01-486-4185
Lockheed Martin P/N: 77A119757P1
The post ETI0001-1447 Series, 2000 VA UPS, with Intelligent PDU for AN/SQQ89 appeared first on Rugged Systems.
]]>The heavy-duty chassis occupies only 3U (5.25”) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for both domestic(115 VAC, CONUS) and optional auto-ranging international input voltages (230 VAC,OCONUS). Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments.. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battle-short override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection. This panel is also equipped with the EPO (Emergency Power Off) feature. EPO requires pressing two switches at opposite ends of the panel to avoid accidental operation. EPO will trip the input circuit breaker on the front of the UPS, removing all power from the unit and the loads.
The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are unique allowing the use of either standard NEMA 5-15P plugs or MS threaded metal shell connectors. This reverse air flow version draws air through the front and exhausts out the rear vent into the rack. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information see the Power Distribution Units section for a listing of stand alone PDUs
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1447 Series, 2000 VA UPS, with Intelligent PDU for AN/SQQ89 appeared first on Rugged Systems.
]]>Standard Product: Boeing / General Dynamics / University of Texas / Navy
Rugged Mil Spec Military Power® Isolated N5 UPS
Ultra Quiet 2000 VA Rack Mount UPS
Integrated 6 Circuit, 2 Pole, Intelligent, Solidstate Power Distribution Unit
The post ETI0001-1444 Series, 2000 VA UPS, with Integrated PDU for US Navy appeared first on Rugged Systems.
]]>The heavy-duty chassis occupies only 3U (5.25”) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The front panel is sealed meeting the Navy drip proof requirements. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis.
The internal shielded input transformer provides galvanic isolation with provisions for both domestic(115 VAC, CONUS) and optional auto-ranging international input voltages (85-270 VAC,OCONUS). The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The high intensity audible alarm can be heard in high noise environments and includes an audible enable/disable switch. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation.
The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battle short override. Battle short can be engaged via the front panel control to override thermal shutdown. When in Battle-short, an audible alarm is sounded and an indicator is lit. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are unique MS threaded metal shell connectors, each “clocked” differently so only one cable can go to each output. This unit draws air through the side air vents and exhausts out the rear vent into the rack. This allows the unit to be used in either positive, negative or neutral pressure racks. The fan is a special extra quiet version to keep the unit’s overall audible level below 44 dB.
The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information see the Power Distribution Units section for a listing of stand alone PDUs
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1444 Series, 2000 VA UPS, with Integrated PDU for US Navy appeared first on Rugged Systems.
]]>