The field proven Rugged Systems™ UPS line is ideally suited for commercial, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1473AA was specifically designed to meet the stringent requirements of FAA programs including WAAS. The ETI0001-1473AA does not require a separate PDU since the PDU functions are already integrated into the UPS module. This saves rack space, cabling and expense while improving overall reliability.
The heavy-duty chassis, occupying only 5.25”(3U) for the electronics and 3.5″ (2U) for the optional battery module by 22” depth, delivers up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis.
The standard version accepts domestic voltages from 85-135 VAC at full load. At loads less than full load, the input voltage can be even lower. The optional global input version has auto-ranging from 85-270 VAC (CONUS and OCONUS) utilizing an internal input transformer. When ordering the global version, the input circuit breaker and the galvanic isolation transformer provide a double pole isolated source for overseas locations where phase references and grounding are not consistent.
The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 or 50 hertz power switch selectable. The unit can also be ordered with 46-440 hertz input. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The ETI0001-1473AA has the added benefit of having an internally redundant 24 VDC DC power source output.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The front and rear panels also provide easy access to both the AC Input and Battery Input fuses. Coupled with the adjacent spare fuses, MTTR is reduced to less than 15 minutes.
The internal intelligent thermal sensors provide two-stage monitoring of unit temperatures, with both local and remote Inhibit Over Temperature (INHIBIT OVRTMP) capability of thermal shutdown. INHIBIT OVRTMP can be engaged via the front panel control, via a remote contact input or via a software command. When in INHIBIT OVRTMP, an audible alarm is sounded and an indicator is lit. The high-intensity audible alarm can be heard in high noise environments and includes an audible enable/disable/reset switch and an adjustable vane to control the sound level.
All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety. Ten push/pull circuit breakers provide both circuit protection and manual controls. Both the input and load circuit breakers are shock-rated to over 100 Gs. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. This unit draws air through the front air filter and exhausts out the rear vent into the rack. This allows the unit to be used in either negative or neutral pressure racks. The stainless steel ball-bearing fan is a special extra quiet version to keep the unit’s overall audible level below 44 dB.
The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The UPS Remote Control and PDU Remote Control connectors provide an interface to optional remote display/control panels. The RJ45 LAN port provides an SNMP/HTTP interface for various UPS parameters and control of the load outputs. Internal software functions include the ability to Sequence Loads of Startup and to Shed Loads for either Overload or Over temperature or to lengthen battery run time (when used with battery modules). These functions follow a user-defined priority lists and schedules.
The batteries in the optional battery modules are maintenance-free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information:
- ETI0001–1473. NSN: 6130-01-618-6132. ups nrp. Part Number: ETI0001-1151 supply. NSN: 6130-01-619-0093. power supply
- ETI0001-1473AD: ETI00011473AD, 6130-01-643-8805, Power Supply, Uninterruptible, ETI0001-N5(0XBF7), ups, rack mounted, NSN 6130-01-434-3701
- ETI0001-1473AF: Raytheon / FAA WAAS Rugged COTS Product Direct Replacement for 120 VAC PDT NPM-2000, P/N 199-00005-01 Ultra Quiet 2000 VA Rack Mount
- ETI0001-1473A 2.0 kVA 208 VAC Rugged Rackmount COTS WAAS UPS with Internal Intelligent PDU
- ETI0001-1473B 2.0 kVA 208 VAC Rugged Rackmount COTS WAAS UPS with Internal Intelligent PDU
- See the Power Distribution Units section for a listing of stand alone PDUs
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.