The post ETI0001-2241, 2000 VA, UPS with Frequency Converter for Radar Systems appeared first on Rugged Systems.
]]>The heavy-duty chassis,occupying only 5.25″ (3U) of rack space and 18.5″ depth, has rounded metal corners and rugged handles front and rear, aiding in safe handling. The chassis is constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to clean,uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down.The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
Overall, the World Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-2241, 2000 VA, UPS with Frequency Converter for Radar Systems appeared first on Rugged Systems.
]]>The post ETI0001-1285AA, 1500 VA UPS with Frequency Converter appeared first on Rugged Systems.
]]>The heavy-duty chassis,occupying only 5.25″ (3U) of rack space, has rounded metal corners and rugged handles front and rear, aiding in safe handling. The chassis is constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to mechanical shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115/120 VAC, CONUS) and international (220/230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean,uninterruptible 50 or 60 hertz power, switch selectable. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The rear panel provides connectors for the input and output power. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the rear vent, with alternate air flow directions optional.The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information:
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1285AA, 1500 VA UPS with Frequency Converter appeared first on Rugged Systems.
]]>The post ETI0001-1240 Series, 1000 VA and Frequency Converter for USAF appeared first on Rugged Systems.
]]>The heavy-duty chassis, occupying only 3U (5.25″ high) of rack space and 18.5″ depth, has rounded metal corners and rugged handles front and rear, aiding in safe handling. The companion 2U(3.5″ high) Battery Expansion Modules are designed to be daisy chained to bring the backup time to 4 hours in the typical configuration. In the typical ECMO Cart application, the base UPS unit and up to four Battery Modules are mounted in the lower underside section of the patient cart. Both module chassis are constructed of brushed aluminum to minimize overall weight. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. This special transformer and filters result in ultra low input leakage current required for medical applications. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for systems or locations where phase references and grounding are not consistent. For scenarios that need hospital grade power immediately and no AC source is available to run the UPS, the Cold Start push button allows the unit to start and run from its battery modules before external AC is available.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The rear panel provides a locking connector for the input power and six hospital grade NEMA 5-15R output receptacles. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The “ETI0001-1240” has the added benefit of having both an internal battery and external battery expansion modules. The external Battery Modules can be field replaced without having to shut the UPS down. This allows the backup time to be extended even further. The optional Battery Charger/Conditioner (which has aircraft and global input capability) is used to maintain the spare Battery Modules in ready condition at all times. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For other versions of this product, inquire for information on these model numbers:
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1240 Series, 1000 VA and Frequency Converter for USAF appeared first on Rugged Systems.
]]>The post ETI0001-1254, 2000 VA UPS & Frequency Converter for AN/TPS-59 appeared first on Rugged Systems.
]]>The heavy-duty chassis,occupying only 7″ (4U) of rack space and 18.5″ depth, has rounded metal corners and rugged handles front and rear, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean,uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the front vent, with alternate air flow directions optional. The ”
ETI0001-1254″ has the added benefit of having afield replaceable battery via a rear draw out battery module. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.
Overall, the Military Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1254, 2000 VA UPS & Frequency Converter for AN/TPS-59 appeared first on Rugged Systems.
]]>