The post ETI0005-1476, 500 Watt Rugged DC NEMA UPS appeared first on Rugged Systems.
]]>Locking connectors for the input and output power are available as options. Multiple input and output power panel options are also available. A washable intake air filter and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted outside vents. An external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The status D shell connector provides signals to interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
Overall, the PowerStation line is uniquely qualified for critical vehicle, industrial, shipboard, airborne or land-based systems combining advanced modular design features with highly reliable construction.
The post ETI0005-1476, 500 Watt Rugged DC NEMA UPS appeared first on Rugged Systems.
]]>The post ETI0005-1065, 12 VDC Rugged NEMA UPS appeared first on Rugged Systems.
]]>The Energy Technologies’ ETI0005-1065 Redundant DC UPS operates as an online Uninterruptible Power System (UPS) and provides the following capabilities:
Total Intelligent Protection Innovative microprocessor control makes the Redundant DC UPS the most intelligent On-Line UPS system available today. The Redundant DC UPS offers NO switching time that eliminates the most remote chance of data loss from dangerous power gaps. Redundant DC UPS true On-Line design continuously powers the load with regenerated clean sine wave power. It protects all attached equipment and data full-time against damaging sags, glitches, brownouts, surges, spikes, overvoltages, and EMI/RFI noise, as well as blackouts. The Redundant DC UPS provides fully redundant DC power conversions and fully redundant battery backup power virtually eliminating single point failures within the power train.
Brownout Regulation Without Battery Drain The Redundant DC UPS protects your equipment against sustained brownouts and overvoltages indefinitely. Even when the input drops or rises beyond normal limits, the Redundant DC UPS regulates the output without any battery drain. This prevents nuisance alarms and shutdowns caused by the UPS that drain the battery during brownouts. The Redundant DC UPS also ensures that full battery capacity is available to handle blackouts that follow brownouts.
Integrated Line Isolation The Redundant DC UPS incorporates a fully rated Isolation Transformer in the same chassis as the UPS, saving rack space and cabling while improving overall reliability. This transformer separates the input power from the output power, which is critical in applications such as shipboard or locations where grounding is in question.
Serviceability The Redundant DC UPS internal design is modular. Internally, the Redundant DC UPS contains a Battery Module and a Power Supply Module. Both the Battery Module and the Power Supply Module are equipped with captive hardware designed to improve service time. The Power Supply Module also contains a Test Point Panel, which allows quick and easy access points to test the Redundant DC UPS.
The post ETI0005-1065, 12 VDC Rugged NEMA UPS appeared first on Rugged Systems.
]]>The post ETI0005-1030AA, 3000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>Locking connectors for the input and output power are available as options. Multiple input and output power panel options are also available. A washable intake air filter and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted outside vents. An external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60 hertz. The status D shell connector provides signals to interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
Overall, the PowerStation line is uniquely qualified for critical industrial, shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
Also available:
| • ETI0005-1030 | 120/240 VAC, 50/60 Hz | 3 kVA | 120 VAC, 50/60 Hz | |
| • ETI0005-1030AA | 120VAC, 50/60Hz | 3 kVA | 120VAC, 50/60Hz |
The post ETI0005-1030AA, 3000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>The post ETI0005-1030, 3000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>Locking connectors for the input and output power are available as options. Multiple input and output power panel options are also available. A washable intake air filter and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted outside vents. An external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60 hertz. The status D shell connector provides signals to interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
Overall, the PowerStation line is uniquely qualified for critical industrial, shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
Also available:
| • ETI0005-1030 | 120/240 VAC, 50/60 Hz | 3 kVA | 120 VAC, 50/60 Hz | |
| • ETI0005-1030AA | 120VAC, 50/60Hz | 3 kVA | 120VAC, 50/60Hz |
The post ETI0005-1030, 3000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>The post ETI0005-1016AG, 1000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>Locking connectors for the input and output power are available as options. Multiple input and output power panel options are also available. A washable intake air filter and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted outside vents. An external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60 hertz.
Overall, the PowerStation line is uniquely qualified for critical industrial, shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
Also available:
| • ETI0005-1016 | 120/240 VAC, 50/60 Hz | 1 kVA | 120 VAC, 50/60 Hz | 80 min | Autoranging | ||
| • ETI0005-1016AB | 120VAC, 50/60Hz | 1 kVA | 120VAC, 50/60Hz | 120 min | MANUAL BYPASS SWITCH/Mil-Spec | ||
| • ETI0005-1016AD | 120VAC, 50/60 Hz | 2 kVA | 120 VAC, 50/60 Hz | No Batt. | MANUAL BYPASS SWITCH |
The post ETI0005-1016AG, 1000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>PowerStation™Isolated UPS
2.0 KVA
120VAC/120VAC
50/60Hz
Isolation
Alarm Summary
120 Minute Battery Back Up @ 8 Amps
The post ETI0005-1016AD, 2000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>Locking connectors for the input and output power are available as options. Multiple input and output power panel options are also available. A washable intake air filter and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted outside vents. An external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down.
A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60 hertz. The status D shell connector provides signals to interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. Overall, the PowerStation line is uniquely qualified for critical industrial, shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
Also available:
| • ETI0005-1016 | 120/240 VAC, 50/60 Hz | 1 kVA | 120 VAC, 50/60 Hz | 80 min | MANUAL BYPASS SWITCH/Mil-Spec | ||
| • ETI0005-1016AB | 120VAC, 50/60Hz | 1 kVA | 120VAC, 50/60Hz | 120 min | MANUAL BYPASS SWITCH | ||
| • ETI0005-1016AG | 120/240 VAC, 50/60 Hz | 1 kVA | 120 VAC, 50/60 Hz | No Batt. | Autoranging |
The post ETI0005-1016AD, 2000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>The post ETI0005-1016AB, 1000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>An internal transformer bay accommodates the input isolation transformer with provisions for both domestic and optional international voltages for ratings up to 1000 VA. The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. Various optional power distribution controls are available which mount internally or remotely.
Locking connectors for the input and output power are available as options. Multiple input and output power panel options are also available. A washable intake air filter and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted outside vents. An external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down.
A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60 hertz. The status D shell connector provides signals to interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. Overall, the PowerStation line is uniquely qualified for critical industrial, shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
Also available:
| • ETI0005-1016 | 120/240 VAC, 50/60 Hz | 1 kVA | 120 VAC, 50/60 Hz | 80 min | MANUAL BYPASS SWITCH/Mil-Spec | ||
| • ETI0005-1016AD | 120VAC, 50/60Hz | 2 kVA | 120VAC, 50/60Hz | 120 min | MANUAL BYPASS SWITCH | ||
| • ETI0005-1016AG | 120/240 VAC, 50/60 Hz | 1 kVA | 120 VAC, 50/60 Hz | No Batt. | Autoranging |
The post ETI0005-1016AB, 1000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>The post ETI0005-1016, 1000 VA Rugged NEMA UPS appeared first on Rugged Systems.
]]>Locking connectors for the input and output power are available as options. Multiple input and output power panel options are also available. A washable intake air filter and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted outside vents. An external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60 hertz. The status D shell connector provides signals to interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
Overall, the PowerStation line is uniquely qualified for critical industrial, shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
Also available:
| • ETI0005-1016AB | 120/240 VAC, 50/60 Hz | 1 kVA | 120 VAC, 50/60 Hz | 80 min | MANUAL BYPASS SWITCH/Mil-Spec | ||
| • ETI0005-1016AD | 120VAC, 50/60Hz | 2 kVA | 120VAC, 50/60Hz | 120 min | MANUAL BYPASS SWITCH | ||
| • ETI0005-1016AG | 120/240 VAC, 50/60 Hz | 1 kVA | 120 VAC, 50/60 Hz | No Batt. | Autoranging |