The post ETI0001-1460, 4000 VA, with integrated Power Conditioner and PDU appeared first on Rugged Systems.
]]>The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis.
The optional global input version has auto-ranging from 85-270 VAC (CONUS and OCONUS) utilizing an internal input transformer. When ordering the global version, the input circuit breaker and the galvanic isolation transformer provide a double pole isolated source for overseas locations where phase references and grounding are not consistent.
The unit can also be ordered with 46-440 hertz input. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The ETI0001-1460 has the added benefit of having an internally redundant 24 VDC DC power source output.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment.
All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety. Ten push/pull circuit breakers provide both circuit protection and manual controls. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. This unit draws air through the front air filter and exhausts out the rear vent into the rack. This allows the unit to be used in either negative or neutral pressure racks.
The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The UPS Remote Control and PDU Remote Control connectors provide an interface to optional remote display/control panels. The RJ45 LAN port provides an SNMP/HTTP interface for various UPS parameters and control of the load outputs. Internal software functions include the ability to Sequence Loads of Startup and to Shed Loads for either Overload or Over temperature or to lengthen battery run time (when used with battery modules). These functions follow a user-defined priority lists and schedules.
The batteries in the optional battery modules are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information:
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.
Also Available: ETI0001-1460AA
The post ETI0001-1460, 4000 VA, with integrated Power Conditioner and PDU appeared first on Rugged Systems.
]]>The post ETI0001-1460AA, 4000 VA, with integrated Power Conditioner and PDU appeared first on Rugged Systems.
]]>The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis.
The optional global input version has auto-ranging from 85-270 VAC (CONUS and OCONUS) utilizing an internal input transformer. When ordering the global version, the input circuit breaker and the galvanic isolation transformer provide a double pole isolated source for overseas locations where phase references and grounding are not consistent.
The unit can also be ordered with 46-440 hertz input. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The ETI0001-1460AA has the added benefit of having an internally redundant 24 VDC DC power source output.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment.
All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety. Ten push/pull circuit breakers provide both circuit protection and manual controls. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. This unit draws air through the front air filter and exhausts out the rear vent into the rack. This allows the unit to be used in either negative or neutral pressure racks.
The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The UPS Remote Control and PDU Remote Control connectors provide an interface to optional remote display/control panels. The RJ45 LAN port provides an SNMP/HTTP interface for various UPS parameters and control of the load outputs. Internal software functions include the ability to Sequence Loads of Startup and to Shed Loads for either Overload, or Over temperature or to lengthen battery run time (when used with battery modules). These functions follow a user defined priority lists and schedules.
The batteries in the optional battery modules are maintenance free with immobilized electrolyte and are constructed of flame retardant materials.
For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
For more information:
Overall, the Outdoor Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-1460AA, 4000 VA, with integrated Power Conditioner and PDU appeared first on Rugged Systems.
]]>
The post ETI0001-2219 Series, 4000 VA for AN/BLQ-10 appeared first on Rugged Systems.
]]>There will be more information coming soon about this product line.
If you have inquiries about this product, please use the field below.
This series consists of these units:
Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-2219 Series, 4000 VA for AN/BLQ-10 appeared first on Rugged Systems.
]]>NSN: 6130-01-494-1998
The post ETI0001-2215 series, 4000 VA, Rugged Mil Spec UPS for Submarines appeared first on Rugged Systems.
]]>The 3U electronics module can be mounted in the upper section of the rack near eye level or lower in the rack near the battery module. The heavier 2U battery module is usually mounted in the bottom of the rack for lowering the center of gravity of the rack. A heavy duty shielded cable is provided to connect the two modules. Both chassis have rounded metal corners and rugged handles, both front and rear, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration in any axis. These units can be mounted horizontally or vertically.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments.All controls and protective devices are brought to front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console,or on the unit front panel with only a logic level cable connection.
The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are MS threaded metal shell connectors. This unit draws air through the front and exhausts out the rear vents into the rack.This allows the unit to be used in either negative or neutral pressure racks. A removable and washable intake air filter and high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The external battery connector allows the safe and easy addition of the standard or extra battery modules without having to shut the unit down.The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
Overall, the Military Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
The post ETI0001-2215 series, 4000 VA, Rugged Mil Spec UPS for Submarines appeared first on Rugged Systems.
]]>