The field-proven Rugged Systems™ Power Distribution Unit (PDU) line is ideally suited for military, industrial and telecommunications applications requiring a rugged rack, vehicular or field-deployable, high reliability, compact size and lightweight design. The rounded metal corners aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. All controls and protective devices are brought to the front panel. Further, all front panel devices are recessed with critical switches or breakers guarded to prevent damage or accidental operation.

Power Distribution Units (PDU)

ETI offers as part of its PowerStation line, individual branch circuit control.  The Power Distribution Units (PDU) can be integrated as part of the UPS unit or as separate modules.  Each of the PowerStation UPS products offers up to six (6) branch circuits integrated into the UPS module with individual circuit protection and power outlets.  The circuit protection can be breakers, fuses, or switches.  The power outlets can be standard, twist-lock, or military receptacles or terminal blocks.  If more than six (6) circuits are needed, the PowerStation PDU Module can provide up to sixteen (16) circuits in groups of four (4).  Custom configurations are also available.

Distribution Load Control

In conjunction with the PDU functions (in either the UPS configuration or the separate PDU Module), each of the individual circuits can be remotely controlled ON or OFF.  External dry contacts are connected via a second DB-25 connector to control these circuits.  This optional function is extremely useful in applications requiring remote control of loads or safety interlock features (de-energize equipment when racked out).  The low-energy 5 VDC logic and encapsulated solid-state power relays are safe for almost any environment.

Selective Load Shedding

As a further enhancement to the Distribution Load Control, the Selective Load Shedding feature allows the user to select less critical loads that can be shed during a power outage to extend the battery reserve time for the more critical loads.

Thermal Load Shedding

Distribution Load Control is equipped with an optional two-stage thermal shutdown feature.  The sensors can be mounted in the equipment racks or remotely.  The first stage turns ON an LED indicator and generates an audible alarm and the second stage will shed either selected or all connected loads.  This function is useful in uncontrolled or remote environments.

Dual Source Input

The PowerStation UPS is available with a Dual Source Input with Input 1 as the primary source and Input 2 as the alternate source. If Input 1 fails, the unit automatically transfers to the secondary source, Input 2. When Input 1 returns to normal, the unit automatically returns to that source. The Dual Source Input option is available with either the standard UPS configuration or with the Power Conditioning Only option providing an added degree of reliability to critical loads.

ETI0003-1086 Smart DC Power Distribution Unit

Rugged Rackmount Power Distribution Unit
with Dual Phase Input/ 12 Controlled Outputs

  • Rugged Power
  • ETI0003-1086 Rugged Rack Mount PDU
  • 100 Amp/24/48 nominal
  • 12 controlled outputs w/1 pole circuit breakers

The field-proven Rugged Systems™ Power Distribution Unit (PDU) line is ideally suited for military, industrial and telecommunications applications requiring a rugged rack, vehicular or field-deployable, high reliability, compact size and lightweight design. The rounded metal corners aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. All controls and protective devices are brought to the front panel. Further, all front panel devices are recessed with critical switches or breakers guarded to prevent damage or accidental operation.

Power Distribution Units (PDU)

ETI offers as part of its PowerStation line, individual branch circuit control.  The Power Distribution Units (PDU) can be integrated as part of the UPS unit or as separate modules.  Each of the PowerStation UPS products offers up to six (6) branch circuits integrated into the UPS module with individual circuit protection and power outlets.  The circuit protection can be breakers, fuses, or switches.  The power outlets can be standard, twist-lock, or military receptacles or terminal blocks.  If more than six (6) circuits are needed, the PowerStation PDU Module can provide up to sixteen (16) circuits in groups of four (4).  Custom configurations are also available.

Distribution Load Control

In conjunction with the PDU functions (in either the UPS configuration or the separate PDU Module), each of the individual circuits can be remotely controlled ON or OFF.  External dry contacts are connected via a second DB-25 connector to control these circuits.  This optional function is extremely useful in applications requiring remote control of loads or safety interlock features (de-energize equipment when racked out).  The low-energy 5 VDC logic and encapsulated solid-state power relays are safe for almost any environment.

Selective Load Shedding

As a further enhancement to the Distribution Load Control, the Selective Load Shedding feature allows the user to select less critical loads that can be shed during a power outage to extend the battery reserve time for the more critical loads.

Thermal Load Shedding

Distribution Load Control is equipped with an optional two-stage thermal shutdown feature.  The sensors can be mounted in the equipment racks or remotely.  The first stage turns ON an LED indicator and generates an audible alarm and the second stage will shed either selected or all connected loads.  This function is useful in uncontrolled or remote environments.

Dual Source Input

The PowerStation UPS is available with a Dual Source Input with Input 1 as the primary source and Input 2 as the alternate source. If Input 1 fails, the unit automatically transfers to the secondary source, Input 2. When Input 1 returns to normal, the unit automatically returns to that source. The Dual Source Input option is available with either the standard UPS configuration or with the Power Conditioning Only option providing an added degree of reliability to critical loads.

Technical Specifications

AC INPUT FROM RACK
PDU input from rack: 24/28 nominal
Input Main connection: GTS02R22-22P
Input control/protection: 1 pole, 100 am circuit breaker
Input power indicator: Green neon lamp
POWER DISTRIBUTION
PDU output voltage to loads: Same as input from rack
Output ratings to loads: Limited to lesser of 25 amps/1-11 load
LOAD 12 40AMP (100 amps TOTAL)
Output circuits: 12 controlled outputs w/1 pole circuit breakers
LOADS (J2 – J11): J12 M55181/4-01 (J12 D38999/24WG11SN)
MECHANICAL
Dimensions (H x D x W): 3.5 (2U) x 15.0 x 19.0 in (approx.)
Rack Slide Mount Patterns: Slides or rear support mounting brackets
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Shipping weight: 43 lb  with lift handles front
Audible noise: Less than 47 dB @ 5.0 ft., ANSI “A” scale
Cooling type: Positive
ENVIRONMENTAL
Storage temperature: -13° to 140° F ambient (-25° to 60° C )
Operating temperature: 32° to 122° F ambient (0° to 50° C ), higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Operating elevation: Up to 10,000 ft (3,0448 m), higher optional

Product Support Services

Warranty Coverage

  1. First Year Standard Warranty- The Energy Technologies’ Standard Warranty covers labor and material (excluding batteries) for the first year after shipment; however, this warranty excludes travel and living expenses. Refer to the Warranty section of this manual.
  2. Extended Warranty (Optional)- For those customers who desire to purchase service over and above the Standard Warranty, ETI will provide a quote for a service plan to meet your requirements. Typical plans include the following:
  3. Extended Warranty OptionThis plan provides for replacement parts as an extension to the Standard Warranty one-year period.
  4. Limited Full Service Plan OptionThe Limited Full Service Plan extends the Standard Warranty beyond the initial one-year period, and includes travel and living expenses for the warranty period. This plan can be offered with or without preventive maintenance.

 

Return Material Authorization

If the product requires service for any reason, the customer should contact the Customer Service Department. If the product must be returned to ETI for repair or replacement, the customer must obtain a Return Materials Authorization (RMA) number. The product must be packed in the original shipping container or other equally suitable container. The product must be shipped prepaid with the RMA number on the packing slip. Unauthorized returns of units will be subject to an inspection and handling charge plus any repair and all transportation charges.

Note

If you have to return the unit for repair, it is imperative that it be packaged properly! Due to the weight of the unit and the potential for mishandling, the unit carton must be strapped to a skid before shipping. This forces the freight company to use a tow motor to move the unit. When a skid is not used, there are stages in handling where the carton will be manhandled and inevitably gets dropped on its ends. Foam packs and other packing fillers alone are not adequate to avoid mechanical damage. Energy Technologies, Inc. will not be liable and a breach of warranty will occur if:
1) a skid is not used
2) proper handling is not maintained.

 

Standard Warranty Policy

Energy Technologies, Incorporated (ETI) warrants against faulty materials or workmanship for equipment sold new and delivered pursuant to the terms of any agreement between ETI and customer for one (1) year from the original date of shipment of the equipment. The warranty is limited to repair or replacement during the warranty period at the sole discretion of ETI. It is the responsibility of the customer to notify and return the defective product to ETI, with all costs for shipment of the product to and from ETI paid by the customer. The defective product must be returned intact and shall appear to ETI upon inspection that the failure of the product was caused by defective material or workmanship. Such repair or replacement shall be made free of charge if the defect is determined to be caused from faulty material and/or workmanship, the unit is within the warranty period, and ETI was notified within the warranty period.

This warranty, however,
(a) extends only to, and is intended for the benefit only of, customer (original purchaser), and does not obligate, and shall not be construed to obligate, ETI to any person or organization other than customer.
(b) is effective only when customer returns such defective part or parts to ETI’s factory, transportation prepaid, immediately upon customer’s discovery of the defect in question.
(c) is not effective when the part or product in question is, or has been, operated beyond rated capacity, used or applied improperly, or used with parts which are not made or recommended by ETI.
(d) does not render ETI liable for any claims or claims for damages which may result, directly or indirectly, from any defect in any part or parts manufactured by ETI; except to replace the part or parts in question.

In lieu of returning defective part or parts to ETI’s factory as specified in subparagraph (b) of the foregoing standard warranty, the customer may request ETI to make necessary repairs on site. If ETI agrees that such on-site repairs are practical, ETI shall supply parts and labor for this purpose free of charge; however, the customer shall pay ETI’s traveling expenses to and from said site and living expenses of such personnel while traveling and while on site. If the required repairs are found to be caused by the mishandling, misuse or misapplication of equipment furnished by ETI and/or the required repairs are covered by the ETI Operations and Maintenance Manual, then ETI shall supply labor at the per diem rate normally charged for field service. Parts to be in accordance with ETI’s spare parts prices.

The warranty shall be void if:
(a) the equipment is damaged by the customer, is improperly used, is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifications.
(b) the equipment is repaired or modified by anyone other than ETI or ETI approved personnel.
(c) has been used in a manner contrary to the products operating manual or other written instructions.

ETI reserves the right to make changes, additions, and/or improvements in its products without incurring any obligation to install them on its products previously manufactured and/or sold. No provision of this warranty shall cover the installed batteries. However, the battery manufacturer’s warranties shall be passed through to the customer whenever applicable. ETI will not be liable for any associated costs incurred by the user or installing contractor as a direct or indirect result of failure or in the replacement of defective in-warranty material. The customer MUST obtain a Return Material Authorization from ETI’s Customer Service Department before returning a product for warranty service. The return authorization number MUST be placed on the outside of the shipping box and the equipment must be packaged securely to avoid damage during shipping. Unauthorized returns for in-warranty repairs may be rejected or subject to an inspection and handling charge of $75 plus any repair and all transportation charges.

The warranty is expressly in lieu of all other warranties, expressed or implied, including, and without limitation, any implied warranty or merchantability or fitness for a particular purpose, and/or any other obligation or liability on the part of Energy Technologies Inc. The sole exclusive remedy for breach of any warranty, expressed or implied, concerning ETI’s products and the only obligation of ETI hereunder, shall be the repair or replacement of defective equipment, components, or parts, or, at ETI’s option, the refund of the purchase price or substitution with a new replacement product. ETI shall in no way be responsible for any consequential damages, of any kind, or nature whatsoever, resulting from the breach of any warranty.

Tell Us About Your Needs

*(denotes required field)
prime contractors

Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466

// code for product search below