Works with Rugged Power UPS Products and Battery Modules

ETI uses the highest quality, maintenance-free, immobilized electrolyte, lead-acid batteries in all of its Rugged Power™, World Power™ and Military Power® UPS products. However as with all lead-acid batteries, there is an internal self discharge that will over time discharge the battery when not being charged. Three basic factors effect the shelf life of batteries: the charge state when stored, the storage temperature, and the length of time stored without being recharged. A battery should never be stored in a discharged state, otherwise it will form lead sulfate that permanently damages the battery. With some projects stretching out over many months, maintaining the charge state of the batteries in the UPS can be a problem. Secondly, attempting to stock spare battery packs or modules for deployed units becomes an even more difficult task since they do not have their own charger like the UPS.

Designed for either in a rack or on a bench top, the ETI0001-1132 Charger/Conditioner is ideally suited for periodic or continuous maintenance of the batteries in the UPS as well as spare Battery Modules. The ETI0001-1132 is specifically designed to support ETI UPS products. The heavy-duty chassis, occupying only limited rack space, has rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The front panel meters and LEDs keep the operator informed as to the unit’s status including charge voltage, current, and charge state. All controls and protective devices are brought to front panel and are recessed to prevent damage or accidental operation. The rear panel provides locking connectors for the input and output power. The four output connectors use adapter cables to interface directly with the UPS units and/or with the spare battery modules. An output selector switch allows the operator to choose between the three nominal outputs. Output current is specifically regulated for optimal battery life, including compensating for ambient temperatures.

In addition to maintaining the correct charge on the battery, the ETI0001-1132 has a Battery Conditioner Section. Battery Conditioning is initiated by pressing a switch on the front panel. This starts a programmed cycle beginning with the first battery connected. It performs a gradual discharge of the battery to a specific level, then begins recharging the battery. This discharge/recharge cycle serves to freshen the battery so that it can perform better on demand. Once it has completed this cycle on the first battery connected, it starts the same cycle with each subsequent battery connected.

The internal input transformer provides galvanic isolation with provisions for both domestic (115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. The auto-ranging input voltage selection allows inputting either 115 VAC or 230 VAC without having to open the enclosure. The input switch and the galvanic isolation transformer provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

Overall, the ETI0001-1132 provides a reliable yet simple solution to the issue of maintaining UPS batteries while in storage.

ETI0001-1132 Intelligent Universal UPS Battery Charger

  • P/N: ETI0001-1132
  • NSN 6130-01-521-0344
  • Works with UPS Products & Battery Modules

Works with Rugged Power UPS Products and Battery Modules

ETI uses the highest quality, maintenance-free, immobilized electrolyte, lead-acid batteries in all of its Rugged Power™, World Power™ and Military Power® UPS products. However as with all lead-acid batteries, there is an internal self discharge that will over time discharge the battery when not being charged. Three basic factors effect the shelf life of batteries: the charge state when stored, the storage temperature, and the length of time stored without being recharged. A battery should never be stored in a discharged state, otherwise it will form lead sulfate that permanently damages the battery. With some projects stretching out over many months, maintaining the charge state of the batteries in the UPS can be a problem. Secondly, attempting to stock spare battery packs or modules for deployed units becomes an even more difficult task since they do not have their own charger like the UPS.

Designed for either in a rack or on a bench top, the ETI0001-1132 Charger/Conditioner is ideally suited for periodic or continuous maintenance of the batteries in the UPS as well as spare Battery Modules. The ETI0001-1132 is specifically designed to support ETI UPS products. The heavy-duty chassis, occupying only limited rack space, has rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The front panel meters and LEDs keep the operator informed as to the unit's status including charge voltage, current, and charge state. All controls and protective devices are brought to front panel and are recessed to prevent damage or accidental operation. The rear panel provides locking connectors for the input and output power. The four output connectors use adapter cables to interface directly with the UPS units and/or with the spare battery modules. An output selector switch allows the operator to choose between the three nominal outputs. Output current is specifically regulated for optimal battery life, including compensating for ambient temperatures.

In addition to maintaining the correct charge on the battery, the ETI0001-1132 has a Battery Conditioner Section. Battery Conditioning is initiated by pressing a switch on the front panel. This starts a programmed cycle beginning with the first battery connected. It performs a gradual discharge of the battery to a specific level, then begins recharging the battery. This discharge/recharge cycle serves to freshen the battery so that it can perform better on demand. Once it has completed this cycle on the first battery connected, it starts the same cycle with each subsequent battery connected.

The internal input transformer provides galvanic isolation with provisions for both domestic (115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. The auto-ranging input voltage selection allows inputting either 115 VAC or 230 VAC without having to open the enclosure. The input switch and the galvanic isolation transformer provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

Overall, the ETI0001-1132 provides a reliable yet simple solution to the issue of maintaining UPS batteries while in storage.

Additional information

Weight 115 lbs
Dimensions 15 × 19 × 3.5 in

Technical Specifications

DC OUTPUT
Output voltage 48, 72 or 78 VDC nominal switch selectable
Output rating: 2 amps max, current limited
Non-linear load capacity: Up to 100% non-linear load capability
Output voltage regulation: intelligent voltage regulation for optimum battery charge rate
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Operational status: Output voltmeter
Output ammeter
Status LEDs
AC INPUT
Input voltage selection: Autoranging from nominal 115 VAC to 230 VAC
+15% -25%, or 85-135 and 170-270
Input frequency: From 46 to 440 Hz
Input/output isolation: 2000 VA,
120 dB common mode,<5mA leakage
Input transient suppression: Complies with ANSI C62.41 1980, IEEE 587
Input control/protection: Guarded 2 pole switch (S1) w/fuse (F2)
Input power connection: MS 3102A-22-2P, 3 pin, locking,
DISTRIBUTION PANEL 
Output circuits: Four outputs standard
Output receptacle: AMP CPC, 3 pin locking
MECHANICAL
Dimensions   ( H x D x W ): 3.50 (2U) x 15.0 x 19.0 in  (89x381x483mm)
Rack slide mount patterns: General Devices slide pattern
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight: 20 lb. (9 kg) with lift handles front and rear
Audible noise: Less than 47 dB @ 5.0 ft., ANSI “A” scale
Cooling type: Internal circulation forced air
ENVIRONMENTAL
Storage temperature: -13° to 140° F ambient  (-25° to 60° C)
Operating temperature:  32° to 104° F ambient  ( 0° to 40° C)
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optionally
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 810, 454 & 1399 Shock/Vib/Electrical
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC, Class A