US Navy Archives - Rugged Systems https://ruggedups.com/product-tag/us-navy/ Rugged Power - Global Solutions Fri, 24 Jan 2025 01:00:34 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.5 https://ruggedups.com/wp-content/uploads/2020/07/cropped-header-32x32.jpg US Navy Archives - Rugged Systems https://ruggedups.com/product-tag/us-navy/ 32 32 ETI0001-1229AB, 2000 VA Rugged Rackmount UPS w Auto-Select https://ruggedups.com/product/eti0001-1229ab-2000-va-rugged-rackmount-ups/ Fri, 28 Jun 2024 14:54:43 +0000 https://ruggedups.com/?post_type=product&p=2008 ETI0001-1229AB
Rugged COTS 2000 VA Rackmount UPS
with Auto-Select Input
  • US Navy /SPAWAR Standard Product
  • Standard N3 Configuration
  • Rugged Power Isolated UPS
  • Rugged UPS Modular Power System

The post ETI0001-1229AB, 2000 VA Rugged Rackmount UPS w Auto-Select appeared first on Rugged Systems.

]]>
The field-proven PowerStation™ UPS line is ideally suited for military, industrial, computer, and telecommunications applications requiring high reliability, rugged construction, compact size, and lightweight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1229AB” was initially designed for US Navy shipboard applications, becoming the standard for several programs.

The heavy-duty chassis occupies only 3U (5.25″) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well-secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. For field-deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high-noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which are mounted on the front panel or remotely.

The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high-capacity stainless steel ball-bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate airflow directions optional. The external battery connector allows the safe and easy addition of extra

battery modules without having to shut the unit down. The batteries are maintenance-free with immobilized electrolytes and are constructed of flame-retardant materials. For more information, see the Battery Technology section. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 50-hertz power. A frequency selection switch is available for those sites requiring 60-hertz output instead of the standard 50-hertz. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shutdown capability.

Inquire for more information on these variants of the 01-1229:

  • ETI0001-1229AA, 2000 VA UPS
  • ETI0001-1229AD, 2000 VA UPS
  • ETI0001-1229AF, 2000 VA UPS
  • See the Power Distribution Units section for a listing of stand-alone PDUs.
  • See the N5 Series ETI0001-1404 for a version of this UPS with an integrated PDU and remote control.

Overall, the Military Power line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.

The post ETI0001-1229AB, 2000 VA Rugged Rackmount UPS w Auto-Select appeared first on Rugged Systems.

]]>
ETI0001-1229AA, 2000 VA Rugged Rackmount UPS https://ruggedups.com/product/eti0001-1229aa-2000-va-rugged-rackmount-ups/ Tue, 09 Mar 2021 15:29:58 +0000 http://ruggedups.com/?post_type=product&p=1483 ETI0001-1229AA
NSN 5996-01-621-7893
Rugged COTS 2000 VA Rackmount UPS
  • US Navy /SPAWAR Standard Product
  • Standard N3 Configuration
  • Rugged Power Isolated UPS
  • Rugged UPS Modular Power System

The post ETI0001-1229AA, 2000 VA Rugged Rackmount UPS appeared first on Rugged Systems.

]]>
The field-proven PowerStation™ UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and lightweight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1229AA” was initially designed for US Navy shipboard applications, becoming the standard for several programs.

The heavy-duty chassis occupies only 3U (5.25″) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. For field-deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high-capacity stainless steel ball-bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate airflow directions optional. The external battery connector allows the safe and easy addition of extra

battery modules without having to shut the unit down. The batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials. For more information, see the Battery Technology section. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 50-hertz power. A frequency selection switch is available for those sites requiring 60-hertz output instead of the standard 50 hertz. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

Inquire for more information on these variants of the 01-1229:

  • ETI0001-1229AB, 2000 VA UPS
  • ETI0001-1229AD, 2000 VA UPS
  • ETI0001-1229AF, 2000 VA UPS
  • See the Power Distribution Units section for a listing of stand-alone PDUs.
  • See the N5 Series ETI0001-1404 for a version of this UPS with an integrated PDU and remote control.

Overall, the Military Power line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.

The post ETI0001-1229AA, 2000 VA Rugged Rackmount UPS appeared first on Rugged Systems.

]]>
ETI0001-1229 series, 2000 VA Rugged Naval / SPAWAR UPS https://ruggedups.com/product/eti0001-1229-series-2000-va-rugged-naval-spawar-ups/ Tue, 22 Sep 2020 18:13:08 +0000 http://ruggedups.com/?post_type=product&p=933 Model: ETI0001-N3A24-I/2.0
Rugged COTS 2000 VA Rackmount UPS
  • US Navy /SPAWAR Standard Product
  • Standard N3 Configuration
  • Rugged Power Isolated UPS
  • Rugged UPS Modular Power System
  • ETI0001-1229AA variant is on NSN: 5996-01-621-7893

The post ETI0001-1229 series, 2000 VA Rugged Naval / SPAWAR UPS appeared first on Rugged Systems.

]]>
The field proven Rugged Power™ UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The “ETI0001-1229″was initially designed for US Navy shipboard applications, becoming the standard for several programs.

The heavy-duty chassis occupies only 3U (5.25″) of rack space while delivering up to2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. For field deployed scenarios, the Cold Start feature allows the unit to run from its battery module before external AC is available. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 50 hertz power. A frequency selection switch is available for those sites requiring 60 hertz output instead of the standard 50 hertz. The Status connector provides an  interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

Inquire for more information on these variants of the 01-1229:

  • ETI0001-1229AA, 2000 VA UPS  NSN 5996-01-621-7893
  • ETI0001-1229AB, 2000 VA UPS
  • ETI0001-1229AD, 2000 VA UPS
  • ETI0001-1229AF, 2000 VA UPS
  • See the Power Distribution Units section for a listing of stand alone PDUs.
  • See the N5 Series ETI0001-1404 for a version of this UPS with an integrated PDU and remote control.

Overall, the Military Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

The post ETI0001-1229 series, 2000 VA Rugged Naval / SPAWAR UPS appeared first on Rugged Systems.

]]>
ETI0001-1202, 1550 VA US Navy, SPAWAR, JMCIS UPS https://ruggedups.com/product/eti0001-1202-1550-va-cots-ups/ Thu, 17 Sep 2020 17:52:59 +0000 http://ruggedups.com/?post_type=product&p=929 Model: ETI0001-N3-I/1.5
Rugged COTS 1550 VA Rackmount UPS

US Navy /SPAWAR StandardProduct Standard N3 Configuration, Rugged Power Isolated UPS
Modular Power System

The post ETI0001-1202, 1550 VA US Navy, SPAWAR, JMCIS UPS appeared first on Rugged Systems.

]]>
The field-proven Military Power® UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size, and lightweight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed, or fixed locations with controlled or uncontrolled environments. The “ETI0001-1202” was initially designed for US Navy shipboard applications, becoming the standard for several programs.

The heavy-duty chassis occupies only 3U (5.25″) of rack space while delivering up to 1550 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning.

The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. The input switch and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent.

The LED arrays keep the operator informed as to the unit’s status including load and battery levels. The high-intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.

The rear panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high-capacity stainless steel ball-bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate airflow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance-free with immobilized electrolytes and are constructed of flame retardant materials. For more information, see the Battery Technology section. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60-hertz power. A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60 hertz. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

See the Power Distribution Units section for a listing of stand-alone PDUs. See the N5 Series for a version of this UPS with an integrated PDU and remote control.

Overall, the Military Power line is uniquely qualified for critical shipboard, vehicle, airborne or land-based systems combining advanced modular design features with highly reliable construction.

 

The post ETI0001-1202, 1550 VA US Navy, SPAWAR, JMCIS UPS appeared first on Rugged Systems.

]]>